4.5 Operational status (display)

The operational statuses are shown on the display of the
inverter.
Fig. 46: "Operational status" display area
Display area showing the operational statuses
1
The following table explains the operational notifications
that can appear on the display:
Display
Explanation
Input voltage on the DC side (photovol-
Off
taic modules) is too low
Electronics are ready for operation,
Standby
DC voltage is still too low for feed-in
Internal control measurements accord-
Starting
ing to VDE 0126
Measurement successful, MPP control
Feed-in (MPP)
active (MPP = maximum power point)
Feed-in is regulated on the basis of
Feed-in regulated
an event (e.g. PV energy is limited
An event is present. Remedial meas-
Event code xxxx
ures can be found in the "Faults" chap-
ter
Tab. 5: Operational notifications on the display of the inverter
03 / 2015 | DOC01361707 | KOSTAL operating manual PIKO inverter 3.0 - 20
4
5
6
Ch. 7, excess temperature, fault)
Ch. 4.10
7
8
9
10
11
12
67