Kostal PIKO Series Operating Manual page 117

Table of Contents

Advertisement

Self-consumption
1
2
3
Select function "Delay in the event of power
9.
loss / fault" and enter time.
Click "Accept".
10.
Start up inverter.
11.
The "Self-consumption control" function is set up.
H
Self-consumption control function 1
Control of self-consumption by time
When a certain rating P1 has been generated for a
certain period of time T1, the inverter switches to
self-consumption.
The inverter remains in self-consumption mode for the
entire run time T2. Following the run time T2, the inverter
ends self-consumption.
This is the end of the interval. This interval can be
repeated several times with the "Activation" option.
P[w]
TA
P1
T1
T2
Fig. 67: Self-consumption graph (Function 1)
P1: Output limit
This is the minimum power (in watts) that must be
produced before the consumer is switched on. You can
enter any value from 1 watt to 999,000 watts.
03 / 2015 | DOC01361707 | KOSTAL operating manual PIKO inverter 3.0 - 20
4
5
6
7
TA
T1
T2
8
9
10
11
t
12
117