Download Print this page

Festo CPX-CM-HPP Brief Description page 14

Cpx terminal
Hide thumbs Also See for CPX-CM-HPP:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Dismantling
1. Loosen the 4 screws of the CPX−CM−HPP.
2. Pull the CPX−CM−HPP carefully and without tilting away
from the contact rails of the interlinking block.
Mounting
1. Place the CPX−CM−HPP in the interlinking block. Make
sure that the corresponding grooves with the power
contact terminals on the bottom of the CPX−CM−HPP lie
above the contact rails.
2. Press the CPX−CM−HPP carefully and without tilting into
the interlinking block up to the stop.
3. Place the screws so that the self−cutting threads can
be used.
4. Tighten the screws by hand in diagonally opposite
sequence. Tightening torque 0.9
14
... 1.1 Nm.
Festo P.BE−K−CPX−CM−HPP 0910NH English