APPENDIX C Configuring and Updating the TPU

C.2 Querying or Changing the TPU IP Address

The TPU IP address is set up at the factory. The factory set default IP address is
192.168.0.81. However, should a different address be required, it can be changed.
To change the TPU IP address:
1.
Connect the supplied null modem cable to the NAV connector of the
TPU and to an available serial port on the SonarPro Workstation.
2. Turn on the SonarPro Workstation and wait for the Windows desktop to appear.
3. Turn on the TPU.
4. Start Linux TPU Updater.
The Klein Linux TPU Updater dialog box opens.
5. Click Read TPU IP Address .
The Select RS-232 Port dialog box shown in Figure C-2 opens.
6. From the Port drop-down list box, select the serial port on the SonarPro
Workstation to which the TPU is connected.
7. From the Rate drop-down list box, select the baud rate of the TPU's NAV serial
port, or select Determine Automatically to have Linux TPU Updater find the rate.
The Klein Linux TPU Updater dialog box opens with the current IP address
displayed in the
Series 5000 V2 Sonar System Operations and Maintenance Manual
Figure C-2:
The Select RS-232 Port Dialog Box.
text box as shown in Figure C-3.