P O W E R L I N K I N G
With this feature you can connect the fixtures to each other using the power cable input and
output sockets. A maximum of 4 fixtures can be connected at 110V, and a maximum 8 fixtures
can be connected at 240V. After the maximum limit has been reached, you will need to use a new
power outlet.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION
OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE!
CHECK SILK SCREEN FOR MAX AMPS.
F U S E R E P L A C E M E N T
Disconnect the unit from its power source. The fuse holder is located next to the power connection
socket. Using a Phillips head screw driver, unscrew the fuse holder. Remove the old fuse and replace
with a shiny new 10A fuse.
C L E A N I N G
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried
out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue,
dust, dew).
T R O U B L E S H O O T I N G
Here are a few common problems that you may encounter along with their solutions.
Unit does not work, No light output, and the fan does not work:
1. Check the power connection and main fuse.
2. Be sure the fuse holder is completely and properly seated.
Not responding to DMX Control:
1. Check the DMX connectors/cables to see if they are linked prop- erly.
2. If the DMX LED is on and no response to the channel, check the address settings and the DMX
controller polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or run alongside to high voltage cable. It may cause
damage or interference to DMX interface circuit.
One of the channels is not working well:
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor's drive IC on the PCB might be out of condition.