Access Power Controllers
MaxFit3F8AP
Fully assembled kit includes:
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACM8 - Fuse Protected Access Power Controller
- One (1) PD8UL - Fuse Protected Power Distribution Module
- BC750 enclosure
MaxFit5F8AP
Fully assembled kit includes:
- One (1) eFlow102NB - Power Supply/Charger
- One (1) ACM8 - Fuse Protected Access Power Controller
- One (1) PD8UL - Fuse Protected Power Distribution Module
- BC750 enclosure
Installation Guide
Rev. MF35KF_052720
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
More than just power.™

Advertisement

loading

Summary of Contents for Altronix MaxFit3F8AP

  • Page 1 Access Power Controllers MaxFit3F8AP Fully assembled kit includes: - One (1) eFlow6NB - Power Supply/Charger - One (1) ACM8 - Fuse Protected Access Power Controller - One (1) PD8UL - Fuse Protected Power Distribution Module - BC750 enclosure MaxFit5F8AP Fully assembled kit includes:...
  • Page 2: Configuration Chart

    Overview: Altronix fused Access Power Controller kits distribute and switch power to access control systems and accessories. They convert a 120VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form “C” contacts. Relays are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc.
  • Page 3 MaxFit3F8AP: NEC Power-Limited Wiring Requirements Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits.
  • Page 4 MaxFit7F5AP: NEC Power-Limited Wiring Requirements Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits.
  • Page 5 Notes: MaxFit3_5F8AP - 5 -...
  • Page 6 Notes: - 6 - MaxFit3_5F8AP...
  • Page 7 - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.