Fused Access Power Controller Kits
Models Include:
MaxFit78AP
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- One (1) AL1024ULXB2 - Power Supply/Charger
- One (1) ACM8 - Fuse Protected Access Power Controller
- One (1) PD8UL - Fuse Protected Power Distribution Module
- BC750 enclosure
MaxFit716AP
16 Door Kit with Fused Outputs
Fully assembled kit includes:
- One (1) AL1024ULXB2 - Power Supply/Charger
- Two (2) ACM8 - Fuse Protected Access Power Controllers
- One (1) PD16W - Fuse Protected Power Distribution Module
- BC750 enclosure
Installation Guide
Rev. MFKLF_051922
Installing Company: _________________________ Service Rep. Name: __________________________________________
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
Address: _________________________________________________________ Phone #: _________________________
MaxFit78APS
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- One (1) AL1024ULXB2 - Power Supply/Charger
- One (1) ACM8 - Fuse Protected Access Power Controller
- One (1) PDS8 - Dual Input Fuse Protected
Power Distribution Module
- One (1) VR6 - Voltage Regulator
- BC750 enclosure
MaxFit716APS
16 Door Kit with Fused Outputs
Fully assembled kit includes:
- One (1) eFlow104NB - Power Supply/Charger
- Two (2) ACMS8 - Dual Input Fuse Protected
Access Power Controllers
- One (1) VR6 - Voltage Regulator
- One (1) PD16W - Fuse Protected Power Distribution Module.
- BC750 enclosure
More than just power.™

Advertisement

loading

Summary of Contents for Altronix MAXIMAL FIT MaxFit78AP

  • Page 1 Fused Access Power Controller Kits Models Include: MaxFit78AP MaxFit78APS 8 Door Kit with Fused Outputs 8 Door Kit with Fused Outputs Fully assembled kit includes: Fully assembled kit includes: - One (1) AL1024ULXB2 - Power Supply/Charger - One (1) AL1024ULXB2 - Power Supply/Charger - One (1) ACM8 - Fuse Protected Access Power Controller - One (1) ACM8 - Fuse Protected Access Power Controller - One (1) PD8UL - Fuse Protected Power Distribution Module...
  • Page 2: Configuration Chart

    Overview: Altronix fused Access Power Controller kits distribute and switch power to access control systems and accessories. They convert a 120VAC 60Hz input into eight (8) or sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form “C”...
  • Page 3 MaxFit78AP: NEC Power-Limited Wiring Requirements Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits.
  • Page 4 MaxFit716AP: NEC Power-Limited Wiring Requirements Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits.
  • Page 5 MaxFit78APS: NEC Power-Limited Wiring Requirements Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits.
  • Page 6 MaxFit716APS: NEC Power-Limited Wiring Requirements Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits.
  • Page 7 Notes: MaxFit ULXB Kits Fused Installation Guide - 7 -...
  • Page 8 7.00” (177.8mm) 7.00” (177.8mm) 1.25” (31.8mm) Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty...

This manual is also suitable for:

Maximal fit maxfit78apsMaximal fit maxfit716apMaximal fit maxfit716aps