Adjusting The Signal Level, Gain And Noise - Dekolink Deko3108S Product Manual

High selectivity 800 mhz midi-repeater
Table of Contents

Advertisement

D
W
L
.
EKOLINK
IRELESS
TD
4.3 A
DJUSTING THE
4.3.1
RF Gain Setting Criteria
The RF Gain is set automatically by the Repeater's SALC function (section 1.3). The
function sets the optimum gain without exceeding the isolation limit.
The gain range is 49-80 dB. The value is set to 80dB by default. The gain is modified
automatically to its optimum value by the SALC mechanism. This mechanism performs
gradual learning of traffic load characteristics and adjusts the Repeater RF Gain
accordingly.
NOTE: The gain can also be set manually. It is recommended to set the Downlink path
gain to a maximum value that is 10 dB below the isolation between the Base antenna
and the Mobile antenna. Use the Max Gain field for Downlink GAIN setting and the Gain
Delta field to determine the GAIN difference between Uplink and Downlink path (Uplink
GAIN follows Downlink GAIN by "Delta" dB).
4.3.2
Adjusting the Signal Levels and Noise
You will now adjust the signal level for complete coverage of the area by adjusting the
signal strength and noise level.
To adjust the signal levels
1. In the topology tree, click Deko3108S.
2. Click the Control and Params tab. The corresponding pane appears.
Note: Be sure to click Send with each change.
Click Send with each
parameter change.
3. Verify that the RF Transmission Enable = ON.
4. Set the Max Power according to your site requirements and click Send.
P/N 300XC10031 Rev. B
D
3108S M
R
EKO
IDI
S
L
, G
IGNAL
EVEL
Proprietary Data
EPEATER
N
AIN AND
OISE
ON (default) – disables
manual RF power selector
located in the Repeater.
P
M
RODUCT
ANUAL
Page 29