3.6 P
U
OWER
P
NOTE: See section 2.1 for power-supply requirements.
To power-up
The Repeater operates from a 100 to 240 VAC Mains. The maximum consumption
power is 150W (typical).
Connect the AC power cable to the Repeaters front panel 100-240VAC connector.
3.7 A
I
NTENNAS
NSTALLATION AND
3.7.1
Antenna Installation Requirements
3.7.1.1 Base (Donor) Antenna
NOTE: Verify that the antennas meet requirements described in section 2.3.1.
Installation requirements:
•
The antenna should point to the direction of the base station for maximum input
power
•
Verify that the antenna is in the base stations line of sight (raise the antenna if
necessary)
•
Install the donor antenna at a higher level (i.e. floor) than the mobile antenna
•
Must be installed at a minimum distance of 1 meter from any personnel within the
area.
3.7.1.2 Mobile (Service) Antenna
NOTE: Verify that the antennas meet requirements described in section 2.3.2.
Installation requirements:
•
Install the service antenna on the ceiling or on the wall so it would shadow the
required coverage area within the in building environment.
•
Installation of this antenna must provide a minimum separation distance of 0.2 m
from any personnel within the area.
•
Cable and jumper loss is at least 2dB.