5.4. RF Gain Setting

The gain range is 59-90 dB and should be set via the RMT software according to the
received power at the Base/Donor antenna, required Output Power at Mobile antenna
and Isolation requirements. Use the Max Gain field for Downlink GAIN setting and the
Gain Delta fields to determine the GAIN difference between Uplink and Downlink path
(Uplink GAIN follows Downlink GAIN by "Delta" dB).
Note: When you set the gain to 60 dB the Maximum Output Power will degrade
due to overload input power the maximum input power you can inject is
–35 dBm.
It is recommended to set the Downlink path gain to a maximum of 12 dB below the
isolation between the Base antenna and the Mobile antenna.