2.3.2
Mobile (Service) Antenna
The Mobile antenna is installed indoors.
Note: Before installing the Mobile antenna, see FCC regulations for information
regarding recommended distances between the antennas and populated areas.
The following describes the requirements for an omni-directional mobile used for indoor
applications.
Specifications:
•
Omni directional antenna with a 0 to 2 dBi typical gain, or wide beam with up to
4dBi gain.
•
Example of omni-directional antenna specifications:
Gain:
VSWR:
Impedance:
Installation requirements:
•
Installation of this antenna must provide a minimum separation distance of 0.2 m
from any personnel within the area.
•
Cable and jumper loss is at least 2dB.
2.4 P
-I
RE
NSTALLATION
Before installing the Repeater, review the following safety information:
•
Follow all local safety regulations when installing the Repeater.
•
Only qualified personnel are authorized to install and maintain the Repeater.
•
During normal operation, the Repeater door should be closed.
•
Some maintenance tasks may require the iDEN midi-repeater door to be opened
while the power is on. In such cases, perform the required tasks carefully and
remember to close the Repeater cover/door when finished.
•
Ground the iDEN midi-repeater with the grounding bolt located on the external
lower side of the cabinet (see 3.5).
•
Do not use the grounding bolt to connect external devices.
•
Follow Electro-Static Discharge (ESD) precautions.
•
Before closing the iDEN midi-repeater cover, make sure no wires are in the way.
•
Use low loss cables to connect the antennas to the Repeater.
2.5 I
NSTALLATION
WARNING! T
HE
-
ALLOW FREE
FLOW OF COOLING AIR
MAY CAUSE DAMAGE TO THE
•
Use a suitable mounting surface, such as a rigid wall.
•
Follow Electro-Static Discharge (ESD) precautions.
•
Install the iDEN midi-repeater close to the service area to monitor the output power
and noise figure.
•
Use low loss cables to connect the antennas to the Repeater.
•
Install the Repeater in a shielded, ventilated, and easy-to-reach area – preferably at
eye level.
Page 14
C
R
OMPACT
EPEATER
0 to 2 dBi
< 2:1
50 ohm
S
I
AFETY
NSTRUCTIONS
L
, E
OCATION
NVIRONMENT AND
R
EPEATER MUST ALWAYS BE INSTALLED VERTICALLY AND TOP
. H
ORIZONTAL INSTALLATION ON A BENCH FOR LONG TIME
R
Proprietary Data
D
3108S
D
EKO
EKOLINK
C
ABLES
-
EPEATER DUE TO OVER
HEATING
W
L
.
IRELESS
TD
-
,
DOWN
TO
.
P/N 300XC10031 Rev. B