B-01 (xx)
WLs LOW BATT
I-01 (xx)
WLs SUPERVN
B-01 (xx)
WLs SUPERVN
- 01 (xx)
CASE TAMPER
WLs TAMPER Bxx
WLs JAMMING Pnl
WLs Supervn Fault
Input (xx)
Wirles Poll Fail
WLs Input /
Input Type
Mismatch
9.2.7 Errors When Setting
Fault
Please leave via
exit door
Exit Via...
Unable To Set
Alarm during the
setting
Alarm during the
setting procedure
Low battery on wireless siren
number 'xx'
Device on wireless input number 'xx'
has not 'checked in'
Wireless siren number 'xx' has not
'checked in' within 20 minutes time
Tamper fault on input number 01
'xx' = any input number
Tamper fault on wireless siren
number 'xx'
Jamming fault on the Enforcer
HomeControl+ Panel
No 'supervision polls' were received
for 20 minutes before the setting
operation. Wireless Input or Bell
input number will be shown so the
problem is easily identified
Wireless Poll Fail displays when no
'polls' (wireless comms) are received
for 20 minutes before the set
operation.
Wireless devices are learned on
inputs but no input types have been
programmed for them.
Description
If the exit mode is programmed as
Final Door, then the premises must
be left through this door for the
system to be set.
If any follow detectors or door
contacts are open during the setting
procedure, a prompt will be
displayed to close them.
A fault condition exists on the
system. Details of the fault will scroll
on the display.
Fail to set time has been exceeded.
Instant inputs have been activated.
Replace the battery on the radio siren
mentioned.
Perform a walk test on the detector, and a
diagnostic signal strength test and then try
replacing the battery.
Test the siren, perform wireless signal
strength diagnostic. Consider replacing the
battery or relocating the siren.
Check the tamper switch on the detector and
make sure the case is closed properly.
Check the tamper switch on the radio siren
mentioned.
Check no radio interference is in close
proximity to the radio devices/panel.
Test the signal strength/battery on each of
the wireless devices.
Test signal strength / battery status for each
wireless device (especially the one that
corresponds to the input named by the fault
message).
Program the input type for each of the
wireless devices learned in the CHANGE
INPUTS.
Solution
Leave via the agreed exit route.
Close all inputs.
Correct the problem if it is an input which is
open, or call an engineer.
Leave the premises within the fail to set
time, increase the fail to set time in 'timers'
or disable this feature in system options.
During the setting procedure do not activate
'instant inputs'.