0020
Exit Starts All
0021
Exit Starts Any
0022
Final Set Any
0023
Strobe Set Fail
0025
Keyswitch Unset
0026
Set with Omit
0028
Power Fault
0029
Confirm Intruder
Any
0030
Confirm HU Any
0031
Entry
0032
Exit
0033
Entry / Exit
0034
Lights
0035
Follow Input
0036
Shunt Fault
0037
Restore 1
0038
Restore 2
0039
PIR Latch 1
0040
PIR Latch 2
0041
Mains Good
0042
Detr Indn Enable
0043
Follow Test
0044
Off During Test
0048
Detr Walk Test
0049
Detector Masked
0050
Follow 24 Hour
At the start of the exit time to set the
LAST area.
When the exit time starts to set the FIRST
area.
When ANY area has been set.
Works similar to output 016, but also fires if the 'set fail' timer expires.
This output turns on for five seconds when the system is disarmed via a
keyswitch input (pulsed or latched).
Active when the system is set with an input omitted.
Active during low volts and battery faults. Restores at code entry after the fault
is cleared.
When more than one intruder alarm
activates.
When more than one confirmed HU
activates.
Active during any entry time.
Active during any exit time.
Active during any entry or exit time.
When the exit or entry timer starts.
Active when a specific input number has been activated. It allows the following
options to be programmed:
-
Follow Type (Follow, Timed, Latched, Code Reset);
-
Follow What (Input, Shunt List, Sub-Area, Area);
-
Follow When (Always, When Armed, When Disarmed);
-
Input to Follow
After an input in the shunt list is opened with an active detector (attempting to
unshunt) the 'Shunt Fault' output pulses until the shunt is reset.
At code entry to set. The normal state of
this input is 0v and it changes to 12v
when activated.
Activates whenever an additional area is
set. The normal state of this input is 0v
and it changes to 12v when activated.
When set (and in Walk Test).
This is the inverse polarity to
PIR Latch 1.
Output showing the 230v mains supply is present.
Output activates during walk test and also when a code is entered to view
detector indications (staying activated for the time that indications are viewed).
Output will activate only when tested from the Engineer menu 'Test Outputs' in
the 'Engineer Tests'. This output can be used as an additional facility for testing
the operation of a Bell. An output programmed to one of these configurations (43
and 44) may be used to trigger a relay to break the hold-off connection to the
Bell – or even to provide the hold-off directly.
Output is normally active and will deactivate only when tested from the Engineer
menu 'Test Outputs' in the 'Engineer Tests' (the same as 43 but opposite
activation).
This output is active during walk test and will only deactivate when all detectors
have been tested.
If any detector goes into 'mask' condition
the output will activate.
If any input programmed as '24 Hour'
activates.
Page: 14
At unset FIRST area (such as no
longer fully set).
At code entry to unset LAST area.
At code entry to unset LAST area.
At next code entry.
At the next code entry.
20 seconds after the set/unset
procedure has completed.
After three seconds.
When unset,
At alarm, or when unset.
At alarm, or when unset.
When the masking fault clears.
When the input is restored.