5.18.10 HU Alarm Stops at:
This feature programs the ending point of alarm responses for a HU alarm: Keypads, Internal
Sounders, Sirens Only, Digi, and Confirm.
5.18.11 Day Alarm Starts at:
This feature programs the starting point of alarm responses for a 24h alarm. The levels are:
Keypads, Internal Sounders, Sirens Only and Digi.
5.18.12 Day Alarm Stops at:
This feature programs the ending point of alarm responses for a 24h alarm: Keypads, Internal
Sounders, Sirens Only and Digi.
5.18.13 Start at:
This feature overrides the settings above. It can be used to create greater flexibility in the use of
the alarm responses feature and, in this case, it is set up for each area if they are in set status
only.
5.18.14 If Areas Set
Select the areas that the following settings will be applicable to.
5.18.15 Stop at:
For example: if Day Alarm is set to Start at Keypad and stop at Keypad, this feature allows set up
for all Areas (if they are set) to make any alarm stop at Digi or Confirm.
5.18.16 If Areas Set
Select the areas that the above setting will be applicable to.

5.19 Set Up Downloading?

The Control Panel has an uploading and downloading capability. The 'InSite' upload/download
software allows you to monitor the status of each input, alter programming and review the logs.
This software is available to download from www.pyronix.com under 'Downloads'. When this
section refers to 'dials the software', this means the PC that the software is installed on. See
section 7 on page 35 for further instruction on different connection methods.

5.20 Software Revision?

This option shows the software version, hub version and Comms module version installed in the
panel. Please obtain the software version number prior to contacting customer support, so that the
correct information can be given upon supporting the product.

5.21 Clean Start?

This option is used to reset the panel to factory default.
5.21.1 Clean Start Code
Currently the system has two default settings. One is EN50131 default and the other default is not
compliant to EN50131. The non EN default code is 2000 and the EN default code is 2020.
NOTE: Notice that the panel comes as defaulted to non EN50131 system and if used under the EN
50131 installation requirements, it MUST be defaulted to EN50131 by using the default code of
2020. Once the factory default code has been applied, the system will be reset to factory defaults.
5.21.2 Clear WLs Data?
This will give the installer the option to clear or not to clear wireless devices if they have been
programmed on the system already.
5.21.3 Clear Codes?
This will give the installer the option to clear or not to clear user codes if they have been
programmed on the system already (The sytem will revert to the default codes).
5.21.4 Clear Logs?
This will give the installer the option to clear or not to clear memory logs if they have been
programmed on the system already.

5.22 Exit Engineer Menu?

There are two ways to exit from the engineer menu. One way is by navigating on the keypad from
this option and the other quick way is by pressing a from any other main menu.