8. Options Programmable Only From PC
The UDL software is available on www.pyronix.com/downloads. The software can be used to
upload/download to the Control Panel and data can be viewed.
Two features that the UDL software incorporates are:
Auto Set and Unset Timer
Logic Gates
For help in the initial software set up, please refer to the UDL software help guides first.
8.1 Auto Set/Unset Timers
This function will allow automatic setting and
unsetting procedures. This is useful when a
premises is left unmanned for a period of time
(such as holidays).
Create a new customer and select 'Euro' and
then scroll to EURO 46 APP
The Auto-Set/Logic Gates will be enabled, click
the 'ok' button.
8.1.1 Adding Set/Unset actions
1. Select 'Add Action'.
2. Select the Day of the week to be Auto-Set.
This will then be displayed in the list.
3. Select the action of this timer (such as
Set)
4. Select the time (24 hour, such as 14:00
NOT 02:00) when the action should start.
5. Another action can now be added (such as
Unset) and select the time for this action.
8.1.2 Adding 'Holidays'
A holiday setting will override any auto-timers that coincide with the holiday. Once the holiday has
passed, it will not repeat.
1. Click 'Add Holiday'
2. Select the dates that are required for the holiday period. These will be displayed at the top right
of the screen under 'Date'.
3. If any holidays are added by mistake, select that holiday and click 'delete'.
NOTE: Make sure that any action already programmed matches correctly when the holiday period
has finished, such as: if the dates January 1st, January 2nd, and January 3rd are selected, the
Control Panel will stay set on all of the dates regardless of the auto-timers. However, an auto-timer
should be set up to unset the day after the holiday has ended if required.
8.2 Areas to Set/Unset
This section of the software selects the areas that will be Set/Unset during the 'Auto Set/Unset'
period.
1. Select the areas to be set and type them in the 'Areas' field.
2. Select the 'Warning Period'. This is a time (in minutes) when the Panel will warn anyone who may
be in the premises that an Auto-Set is about to take place.
NOTE: The warning time is additional to the Auto-Set time, such as: if the Auto-Set time is 22:00, a
warning time of 15 minutes will be added to this, so the actual panel set time will become 22:15. If
the panel must set at 22:00, but a 15 minute warning time is also needed, the Auto-Set time should
be selected as 21:45.
3. Select the 'Delay to Set' time. This is the time used if a person in the premises needs to delay the
auto-timer. If a code is entered on the Control Panel during the Warning Period time, the auto-timer
can be delayed, such as: if the warning period is set to 15 minutes, and the Delay Auto-Set time is
set to 20 minutes, then a user will have a further five minutes before the Auto-Set begins.