DeLaval VMS 2008 Instruction Book page 199

Voluntary milking system
Table of Contents

Advertisement

M
M
m
m
Alarm text
Alarm text
12 14
12 14
ICS Too low
ICS Too low
User
User
milk
milk
notification
notification
temperature
temperature
12 15
12 15
ICS Tank
ICS Tank
User
User
alarm at no
alarm at no
notification
notification
Hygenius
Hygenius
tank
tank
12 16
12 16
ICS
ICS
User
User
Temperature
Temperature
notification
notification
sensor
sensor
broken
broken
12 21
12 21
FCC Low
FCC Low
User
User
cleaning
cleaning
notification
notification
water
water
temperature
temperature
12 22
12 22
FCC
FCC
User
User
Detergent
Detergent
notification
notification
tank is empty
tank is empty
12 23
12 23
FCC
FCC
User
User
Overheat
Overheat
notification
notification
12 24
12 24
FCC Time
FCC Time
Stop alarm
Stop alarm
out water
out water
filling
filling
12 25
12 25
FCC
FCC
User
User
Checksum
Checksum
notification
notification
error in
error in
parameter
parameter
memory
memory
12 26
12 26
FCC
FCC
User
User
Checksum
Checksum
notification
notification
error in
error in
program
program
memory
memory
12 27
12 27
FCC Tank is
FCC Tank is
Stop alarm
Stop alarm
not empty
not empty
after cleaning
after cleaning
2007-12-18
DeLaval voluntary milking system VMS
Type
Type
Meaning
Meaning
Tank alarm.
Tank alarm.
Chilled water is too cold, the
Chilled water is too cold, the
platecooler could freeze.
platecooler could freeze.
Tank alarm.
Tank alarm.
Failure at storage tank.
Failure at storage tank.
Tank alarm.
Tank alarm.
The resistance of the temperature
The resistance of the temperature
sensor is out of the normal range.
sensor is out of the normal range.
Tank alarm.
Tank alarm.
End temperature of the cleaning
End temperature of the cleaning
water is below the temperature
water is below the temperature
set in P30. Possible causes:
set in P30. Possible causes:
a. The temperature of the water
a. The temperature of the water
from the hot-water supply is too
from the hot-water supply is too
low.
low.
b. The amount of hot water in the
b. The amount of hot water in the
water mixture is insufficient.
water mixture is insufficient.
c. Parameter P30 is set to an
c. Parameter P30 is set to an
unrealistic value (standard 40°C).
unrealistic value (standard 40°C).
d. The sieves in the water supply
d. The sieves in the water supply
below the Pre-box are clogged.
below the Pre-box are clogged.
Tank alarm.
Tank alarm.
Possible causes:
Possible causes:
a. One of the detergent containters
a. One of the detergent containters
are empty.
are empty.
b. Detergent is not able to flow into
b. Detergent is not able to flow into
the system.
the system.
Tank alarm.
Tank alarm.
Water temperature exceeds 80°C.
Water temperature exceeds 80°C.
a. Relevant parameters may have
a. Relevant parameters may have
incorrect values.
incorrect values.
b. Contactor may not be working
b. Contactor may not be working
properly.
properly.
Possible causes:
Possible causes:
a. Water valve broken.
a. Water valve broken.
b. Water tap closed.
b. Water tap closed.
c. Water system frozen.
c. Water system frozen.
Tank alarm.
Tank alarm.
A power failure has corrupted the
A power failure has corrupted the
parameter memory.
parameter memory.
Tank alarm.
Tank alarm.
Error in the EPROM.
Error in the EPROM.
Tank alarm.
Tank alarm.
The tank has not been emptied
The tank has not been emptied
after the cleaning.
after the cleaning.
Troubleshooting
Action
Action
Check the temperature of the chilled water.
Check the temperature of the chilled water.
Check the thermostat.
Check the thermostat.
See the manual for the storage tankon what
See the manual for the storage tankon what
actions to take.
actions to take.
Contact service engineer.
Contact service engineer.
Service engineer only:
Service engineer only:
Check for wrong connection.
Check for wrong connection.
If the connection is correct, replace sensor.
If the connection is correct, replace sensor.
Find the cause of the alarm and correct the
Find the cause of the alarm and correct the
error.
error.
a) Replace the container. If the problem
a) Replace the container. If the problem
persists, contact service engineer.
persists, contact service engineer.
b) Service engineer only: check the
b) Service engineer only: check the
cleaning-agent circuit.
cleaning-agent circuit.
a. Check the parameters P29 and P81.
a. Check the parameters P29 and P81.
b. Check the contactor.
b. Check the contactor.
a) Check the water valves (use P90).
a) Check the water valves (use P90).
b) Check tap.
b) Check tap.
c) Defrost the system.
c) Defrost the system.
Use P83 –1 to reset the complete system.
Use P83 –1 to reset the complete system.
Parameters with other settings than the
Parameters with other settings than the
default values must be set again. If
default values must be set again. If
necessary, contact service engineer.
necessary, contact service engineer.
Contact service engineer.
Contact service engineer.
Service engineer only: change the EPROM.
Service engineer only: change the EPROM.
Drain the tank manually.
Drain the tank manually.
94897201.pdf
191(198)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents