DeLaval VMS 2008 Instruction Book page 152

Voluntary milking system
Table of Contents

Advertisement

2
3-4
2007-12-18
2. Remove the silicon hose from the sample
tube and hold the silicone hose.
3. Slowly rewind the silicone hose onto the
tube wheel using a finger.
4. Pull the silicone hose and remove it from
the hole.
Note: Keep finger on the tube wheel to
prevent it revolving too fast. If you let the
tube wheel rotate freely, the spring will be
damaged and must then be replaced.
Remove the
5. Return the wheel slowly to the start
silicone hose
position.
from the hole.
6. To fit a new silicone hose onto the tube
wheel, turn the tube wheel 8 times
clockwise.
7. Push the silicone hose through the hole
in the wheel.
8. Allow the spring to rewind the silicone
hose on to the wheel.
Milk sampler
Maintenance
94897201.pdf
144(198)