DeLaval VMS 2008 Instruction Book page 166

Voluntary milking system
Table of Contents

Advertisement

M
M
m
m
Alarm text
Alarm text
1
1
111 Cow not
111 Cow not
Deviation
Deviation
identified
identified
1
1
112 Unexpected
112 Unexpected
Deviation
Deviation
high yield
high yield
1
1
114 Mumgr
114 Mumgr
Stop alarm
Stop alarm
disconnected
disconnected
1
1
115 Unexpected
115 Unexpected
Deviation
Deviation
low yield
low yield
1
1
117 High MS
117 High MS
User
User
temperature(-
temperature(-
notification
notification
...)
...)
1
1
119 Not cleaned
119 Not cleaned
Stop alarm
Stop alarm
after divert
after divert
1
1
120 Autocalibrati-
120 Autocalibrati-
Deviation
Deviation
on fails
on fails
status ...
status ...
1
1
121 Guardmaster
121 Guardmaster
User
User
block MS
block MS
notification
notification
1
1
122 Guardmaster
122 Guardmaster
Status
Status
allow MS
allow MS
message
message
2007-12-18
DeLaval voluntary milking system VMS
Type
Type
Meaning
Meaning
The cow has not been identified
The cow has not been identified
within the preset time and will be
within the preset time and will be
released.
released.
More milk (50%) than expected
More milk (50%) than expected
has been obtained from a quarter.
has been obtained from a quarter.
The main program in the milking
The main program in the milking
station is deactivated.
station is deactivated.
Less than 40% of the expected
Less than 40% of the expected
yield has been obtained from a
yield has been obtained from a
quarter.
quarter.
Temperature in the system is
Temperature in the system is
above 60 degrees centigrade.The
above 60 degrees centigrade.The
alarm will call the farmer but
alarm will call the farmer but
system will remain in auto mode.
system will remain in auto mode.
Temperature must go below 60
Temperature must go below 60
and up again to trigg a new alarm.
and up again to trigg a new alarm.
A rinse or cleaning should have
A rinse or cleaning should have
been carried out after the last
been carried out after the last
milking, but was not. The selected
milking, but was not. The selected
milk type for the cow is probably
milk type for the cow is probably
"Divert milk" after wich normally
"Divert milk" after wich normally
should follow a cleaning
should follow a cleaning
procedure. (This milk type is used,
procedure. (This milk type is used,
for example, when a cow receives
for example, when a cow receives
some kind of medical treatment.)
some kind of medical treatment.)
Autocalibration of the robot has
Autocalibration of the robot has
failed.
failed.
Additional information: 20 =
Additional information: 20 =
Problem with Balance or PRBS
Problem with Balance or PRBS
calibration. 21 = Problem with
calibration. 21 = Problem with
performance. 30 = Calibration
performance. 30 = Calibration
cancelled by operator. (Previous
cancelled by operator. (Previous
calibration data will be used.)
calibration data will be used.)
US market only. Guardmaster has
US market only. Guardmaster has
been activated and is blocking
been activated and is blocking
movement of robot arm and
movement of robot arm and
magazine.
magazine.
US market only. Guardmaster has
US market only. Guardmaster has
granted normal operation of
granted normal operation of
milking station.
milking station.
Troubleshooting
Action
Action
If identification fails for all cows, contact
If identification fails for all cows, contact
service engineer.
service engineer.
Service engineer only: The time the system
Service engineer only: The time the system
tries to identify a cow can be changed in the
tries to identify a cow can be changed in the
management software (VMS Config).
management software (VMS Config).
If the cow(s) for which the identification
If the cow(s) for which the identification
failed are known, check the transponder(s):
failed are known, check the transponder(s):
Remove the transponder from the cow,
Remove the transponder from the cow,
press "Accept cow" on the touch screen,
press "Accept cow" on the touch screen,
activate the photocell until the entrance
activate the photocell until the entrance
gate is closed, then put the transponder
gate is closed, then put the transponder
close to the transponder. The cow number
close to the transponder. The cow number
associated with transponder should now be
associated with transponder should now be
shown on the touch screen.
shown on the touch screen.
If this alarm appears several times a week,
If this alarm appears several times a week,
make sure that the transponder collars are
make sure that the transponder collars are
loose enough for the transponders to hang
loose enough for the transponders to hang
vertically from the neck of the cows.
vertically from the neck of the cows.
Otherwise, the transponder reader might
Otherwise, the transponder reader might
have difficulty in reading the transponder
have difficulty in reading the transponder
number.
number.
Check the corresponding air-inlet is not
Check the corresponding air-inlet is not
clogged. If the problem persists, contact
clogged. If the problem persists, contact
service engineer.
service engineer.
Restart the milking station. If the problem
Restart the milking station. If the problem
persists, contact service engineer.
persists, contact service engineer.
Check the cow.
Check the cow.
Turn on or increase the flow of cooling air to
Turn on or increase the flow of cooling air to
the electrical cubicle.
the electrical cubicle.
Start a rinse or cleaning manually.
Start a rinse or cleaning manually.
No action is necessary if the robot performs
No action is necessary if the robot performs
well. Inform service engineer if the robot is
well. Inform service engineer if the robot is
not working well.
not working well.
Clear blocking by entering pin code at
Clear blocking by entering pin code at
Guardmaster. This will allow normal
Guardmaster. This will allow normal
operation of milksing station
operation of milksing station
None
None
94897201.pdf
158(198)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents