DeLaval VMS 2008 Instruction Book page 192

Voluntary milking system
Table of Contents

Advertisement

M
M
m
m
Alarm text
Alarm text
5
5
126 Did not get
126 Did not get
Stop alarm
Stop alarm
water from
water from
RA-unit
RA-unit
within...
within...
minutes
minutes
5
5
127 Both low and
127 Both low and
Stop alarm
Stop alarm
high sensor
high sensor
in receiver
in receiver
active
active
5
5
128 Timeout
128 Timeout
Stop alarm
Stop alarm
changing
changing
milk filter
milk filter
5
5
129 Milk diverted
129 Milk diverted
Notfication
Notfication
due to MDi,
due to MDi,
dest %...f
dest %...f
5
5
200 Timeout
200 Timeout
User
User
filling
filling
notication
notication
detergent
detergent
number %...f
number %...f
5
5
201 Timeout
201 Timeout
Stop alarm
Stop alarm
filling water
filling water
in step %...f,
in step %...f,
substep %...f
substep %...f
5
5
202 Timeout
202 Timeout
Stop alarm
Stop alarm
empting
empting
water in step
water in step
%.0f,
%.0f,
substep %.0f
substep %.0f
5
5
203 Too low
203 Too low
Deviation
Deviation
temp at
temp at
filling
filling
%T.0%.0f
%T.0%.0f
min
min
%T.0%.0f
%T.0%.0f
5
5
204 Too low
204 Too low
Deviation
Deviation
temp after
temp after
circulation
circulation
%T...%...f
%T...%...f
min
min
%T...%...f
%T...%...f
5
5
205 Invalid
205 Invalid
Stop alarm
Stop alarm
cleaning
cleaning
config.
config.
2007-12-18
DeLaval voluntary milking system VMS
Type
Type
Meaning
Meaning
Water that should be delivered
Water that should be delivered
from "ReceiveAll" equipment did
from "ReceiveAll" equipment did
not became available within time.
not became available within time.
ReceiveAll is optional, only used at
ReceiveAll is optional, only used at
some installations. Cleaning will be
some installations. Cleaning will be
aborted automaticly.
aborted automaticly.
Level sensor in receiver indicated
Level sensor in receiver indicated
both high and low level at the
both high and low level at the
same time.
same time.
If change of milk filter was started
If change of milk filter was started
but not completed within time this
but not completed within time this
alarm will be given.
alarm will be given.
See alarm text.
See alarm text.
The configured amount of
The configured amount of
detergent was not pumped to
detergent was not pumped to
charging vessel within time.
charging vessel within time.
Cleaning is continued anyhow.
Cleaning is continued anyhow.
Charge vessel was not filled within
Charge vessel was not filled within
time.
time.
Note! If the charge vessel was not
Note! If the charge vessel was not
empty when starting to fill water
empty when starting to fill water
this alarm could be generated at
this alarm could be generated at
start of filling.
start of filling.
The water level in receiver does
The water level in receiver does
not affect the upper level indicator
not affect the upper level indicator
(EndUnitHighLevel is not reached),
(EndUnitHighLevel is not reached),
when sucking water from washing
when sucking water from washing
trough into receiver.
trough into receiver.
Water temperature at filling charge
Water temperature at filling charge
vessel is too low.
vessel is too low.
The return water temperature is
The return water temperature is
measured at end of circulation
measured at end of circulation
cleaning. If this temperature is
cleaning. If this temperature is
below limit set in cleaner
below limit set in cleaner
configuration the alarm will be
configuration the alarm will be
generated.
generated.
Cleaning procedure will not start.
Cleaning procedure will not start.
Troubleshooting
Action
Action
Try to find out why water was not available.
Try to find out why water was not available.
Call serviceman if problem remains.
Call serviceman if problem remains.
Call service technician if several alarms.
Call service technician if several alarms.
Sensor should be checked.
Sensor should be checked.
Make sure the filter change operation is
Make sure the filter change operation is
completed.
completed.
Check the cows that caused the notification.
Check the cows that caused the notification.
Depending on the strategy at the farm the
Depending on the strategy at the farm the
thresholds can be changed. Lowering the
thresholds can be changed. Lowering the
thresholds will increase the
thresholds will increase the
diversion/notifications while increasing the
diversion/notifications while increasing the
threshold will decrease the number of
threshold will decrease the number of
diversions/notifications. The thresholds are
diversions/notifications. The thresholds are
changed in Animal>VMS Cow>Automatic
changed in Animal>VMS Cow>Automatic
diversion.
diversion.
Make sure that there is detergent in the
Make sure that there is detergent in the
container. Check that the hoses are
container. Check that the hoses are
connected to the pump. If the problem
connected to the pump. If the problem
remains call a serviceman.
remains call a serviceman.
Check water pressure, check filters or
Check water pressure, check filters or
strainers in the waterline! Check the water
strainers in the waterline! Check the water
valves! Make sure that the charge vessel is
valves! Make sure that the charge vessel is
empty before being refilled. Check the level
empty before being refilled. Check the level
sensor. If the problem remains call a
sensor. If the problem remains call a
serviceman.
serviceman.
Check vacuum system, check connections
Check vacuum system, check connections
between all 5 teat cups and their jetters.
between all 5 teat cups and their jetters.
(Did you receive "teat cup not tight to jetter"
(Did you receive "teat cup not tight to jetter"
message?) If "EndUnitHighLevel" is
message?) If "EndUnitHighLevel" is
positioned too high, this alarm could be
positioned too high, this alarm could be
generated. If the problem remains call a
generated. If the problem remains call a
serviceman.
serviceman.
Note this temperature check is only done
Note this temperature check is only done
when using hot water. Check boiler, check
when using hot water. Check boiler, check
set point setting in cleaner configuration.
set point setting in cleaner configuration.
Check temperature sensor. If the problem
Check temperature sensor. If the problem
remains call a serviceman.
remains call a serviceman.
Check same at alarm 5:203. If the
Check same at alarm 5:203. If the
installation has long not insulated transport
installation has long not insulated transport
lines the temperature fall could be too big.
lines the temperature fall could be too big.
Check for residual pre-rinse water (purge
Check for residual pre-rinse water (purge
problem).
problem).
Call for service engineer.
Call for service engineer.
94897201.pdf
184(198)

Hide quick links:

Advertisement

Table of Contents
loading