5. Enter the following fields.
State
Mode
Use Sites
Group Access
Initialization Script
Modem Timeout
Caller ID Logging
Modem Command
Check Dial Tone
SLC™ 8000 Advanced Console Manager User Guide
Indicates whether the internal modem is enabled. When enabling, set the
modem to Disabled, Dial-in, Dial-out, and Dial-back. Disabled by default.
The format in which the data flows back and forth.
With Text selected, the SLC unit assumes that the modem will be used for
remotely logging into the command line. Text mode is only for dialing in. This
is the default.
PPP establishes an IP-based link over the modem. PPP connections can be
used in dial-out mode (e.g., the SLC unit connects to an external network) or
dial-in mode (e.g., the external computer connects to the network that the
SLC unit is part of), dial-back (dial-in followed by dial-out), CBCP server and
CBCP client.
Enables the use of site-oriented modem parameters which can be activated by
various modem-related events (authentication, outbound network traffic for dial-
on-demand connections, etc.). Sites can be used with the following modem
states: dial-in, dial-back, dial-on-demand, dial-in & dial-on-demand, dial-back &
dial-on-demand, and CBCP server.
For more information see
Sites (on page
If undefined, any group can access the modem (text login only). If one or more
groups are specified (groups are delimited by the characters ',' (comma) or ';'
(semicolon)), then any user who logs into the modem must be a member of one
of the specified groups, otherwise access will be denied. Users authenticated
via RADIUS may have a group (or groups) provided by the RADIUS server via
the Filter-Id attribute that overrides the group defined for a user on the SLC unit.
A group provided by a remote server must be either a single group or multiple
groups delimited by the characters ',' (comma), ';' (semicolon), or '=' (equals) -
for example "group=group1,group2;" or "group1,group2,group3".
Commands sent to configure the modem may have up to 100 characters.
Consult your modem's documentation for recommended initialization options. If
you do not specify an initialization script, the SLC uses a uses a default
initialization string of:
AT S7=45 SO=0 L1 V1 X4 &D2 &c1 E1 Q0
Note:
We recommend that the modem initialization script always be pre-
pended with AT and include E1 V1 x4 Q0 so that the SLC unit may properly
control the modem.
Timeout for modem connections. Set to No by default.
To configure the modem connection to time out when no traffic is received
choose Yes and enter a value of 1 to 9999 seconds.
Select to enable the SLC unit to log caller IDs on incoming calls. Disabled by
default.
Modem AT command used to initiate caller ID logging by the modem.
Note:
For the AT command, use
presentation, and use
+VCID=2
presentation. This is subject to subscribing to a Caller ID service for the modem
line.
If enabled, the SLC will periodically check the modem for a dial tone while
waiting for a dial in (e.g., if the Modem State is set to Dial-in, or if the Modem
State is set to Dial-back and the SLC unit is in the Dial-in portion of the
sequence). The SLC unit can issue a trap or an event can be setup to notify the
user if no dial tone is detected. Enabled by default (every 15 minutes).
222).
to enable Caller ID with formatted
+VCID=1
to enable Caller ID with unformatted
9: Device Ports