Mellanox Technologies SN2700 Hardware User Manual page 39

1u switch systems
Hide thumbs Also See for SN2700:
Table of Contents

Advertisement

Installation
Before attempting a remote (for example, SSH) connection to the system, check the mgmt0
Step 5.
interface configuration. Specifically, verify the existence of an IP address. To check the current
mgmt0 configuration, enter the following command:
r-qa-sit-switch01 (config) # show interfaces mgmt0
Interface mgmt0 status:
r-qa-sit-switch01 (config) #
You are advised to check the software version embedded in your system, using the command
Step 6.
'show version'. you can continue and compare this version to the latest version that can be
retrieved from Mellanox support site. To upgrade software, simply refer to MLNX-OS user
manual.
2.7.1.3 Remote Connection with MLNX-OS
Once the network attributes are set, you can access the CLI via SSH or the WebUI via HTTP/
HTTPs.
 To access the CLI, perform the following steps:
Set up an Ethernet connection between the system and a local network machine using a stan-
Step 1.
dard RJ45 connector.
Start a remote secured shell (SSH) using the command: "ssh -l <username> <IP_address>",
Step 2.
# ssh -l <username> <ip_address>
Comment:
Admin up:
yes
Link up:
yes
DHCP running:
yes
IP address:
192.168.1.100
Netmask:
255.255.255.0
IPv6 enabled:
yes
Autoconf enabled:
no
Autoconf route:
yes
Autoconf privacy:
no
DHCPv6 running:
no
IPv6 addresses:
1
IPv6 address:
fe80::202:c9ff:fe63:b55a/64
Speed:
1000Mb/s (auto)
Duplex:
full (auto)
Interface type:
ethernet
Interface source:
physical
MTU:
1500
HW address:
00:02:C9:63:B5:5A
RX bytes:
968810197
RX packets:
10982099
RX mcast packets:
0
RX discards:
0
RX errors:
0
RX overruns:
0
RX frame:
0
TX bytes:
1172590194
TX packets:
10921755
TX discards:
0
TX errors:
0
TX overruns:
0
TX carrier:
0
TX collisions: 0
TX queue len:
1000
Mellanox Technologies
Rev 1.2
39