6 Connecting diagrams
6
Connecting diagrams
6.1
One boiler + one direct circuit + one domestic hot water tank
Fig.53
Boiler + 1 direct circuit + 1 domestic hot water tank
7
167
7
3
1a
1
35
2a
30e
119
1 Boiler flow
1a Heating flow direct circuit
2 Heating pump direct circuit
2a Heating return direct circuit
3 6 bar (0.6 MPa) safety valve
7 Automatic air vent
9 Isolation valve
16 Closed expansion vessel
18 Heating circuit fill point
(France: with disconnector according to prevailing
regulations)
24 Domestic hot water tank exchanger primary inlet
25 Domestic hot water tank exchanger primary outlet
26 DHW booster pump
46
IX
38
7
27
27
9
9
34
16
6.1.1
Hydraulic connection
64
27
2
9
9
18
25
30
27 Non-return valve
30 Calibrated and sealed safety unit
France: (7 bar (0.7 MPa) - with opening on the
discharge pipe)
30e Drain valve
31 Independent domestic hot water tank
33 Domestic hot water temperature sensor
34 Modulating boiler pump (primary pump)
35 Low-loss header (accessory)
38 Remote control
64 Direct heating circuit
119 Boiler return
167 Boiler control panel
33
T
24
26
9
27
9
7702684 - v04 - 05092019
31
MW-3000018-06