WWW.STEMMER-IMAGING.COM
Set selected mode
The output is set to selected mode with two brightness settings.
RUc,s,t
Where:
c = output channel (1 to 2, 4 or 8, depending on model)
s = brightness 1 setting in percent (s = 0 to 100)
t = brightness 2 setting in percent (t = 0 to s)
Set pulse mode
The output can be set up to pulse on a trigger input. The delay from
trigger to the start of the pulse, the length of the pulse and the
brightness are configurable.
An error is generated if the brightness setting requires a current
greater than 20A or if the combination of pulse width and setting is
not allowed.
RTc,p,d,s
RTc,p,d,s,r
Where:
c = output channel (1 to 2, 4 or 8, depending on model)
p = pulse width in milliseconds (0.02 to 999)
d = delay from trigger to pulse in milliseconds (0.02 to 999)
s = setting in percent (s = 0 to 999)
r = retrigger delay. This parameter is optional.
Set the Option Flags
REc,m
Where:
c = output channel (1 to 2, 4 or 8, depending on model)
m = flags:
bit 1 =
bit 2 =
Set the Trigger Input
This command sets which input is used for pulse and switch output
modes.
RPc,p
RTxxx LED lighting controllers - User Manual
0
E flag set (error detection enabled)
1
E flag cleared (error detection disabled)
0
P flag set (positive triggers)
1
P flag cleared (negative triggers)