  • Page 1 RC100/120 LED Lighting Controllers Quick Start Guide...
  • Page 2 Deliberate acts of endangerment and vandalism are not covered by this document and must be considered by the installer. While care has been taken in the preparation of this document, Gardasoft Vision Ltd will not accept any liability for consequential losses of any kind except those required by law.
  • Page 3: Table Of Contents

    Connecting a trigger source Initial configuration Pulse and duty cycle limits Pulsed output Internal trigger Ethernet operation (RC120) Using the RC120’s web pages Setting the rating of your light Safety precautions Heat Electrical General Installation guidance (disclaimer) Sicherheit Wärme Elektrik Allgemein Installationsanleitung (Haftungsausschluss) www.gardasoft.com...
  • Page 4 Sécurité 10.1 Chaleur 10.2 Électricité 10.3 Généralités 10.4 Guide d’installation (clause de non-responsabilité)
  • Page 5 Gardasoft RC100/120 controllers Your Gardasoft RC100 or RC120 LED Lighting Controller is designed to be quick and easy to use provided you set up the current of your light and connect the controller to an internal or external trigger. This guide is provided to help you get ‘up and running’ quickly and easily.
  • Page 6: Getting Started With Your Rc1Xx

    When you are satisfied that you understand its basic operation, you are ready to download the full user’s guide, as a PDF, from our website (at www.gardasoft.com/downloads/). That document will provide more information. For example, how to use the range of modes of operation...
  • Page 7: Connecting Your Rc1Xx

    Route low voltage wiring to the RC1xx controller separately from mains wiring. If it is not possible to separate low voltage from mains wiring, ensure that the low voltage wiring has appropriately rated insulation or that you apply supplementary insulation. www.gardasoft.com...
  • Page 8: Connecting A Light

    The trigger input is a Smart input; it accepts a range of sources as trigger inputs which are explained in more detail in the User Manual at www. gardasoft.com. The connections are shown opposite. Note that the Smart input is not isolated. It is ground-referenced to the power supply negative connection.
  • Page 9: Pulse And Duty Cycle Limits

    This Quick Start Guide is mainly concerned with pulse mode operation of your RC1xx controller. For more information on the other modes of operation, see the User Manual at www.gardasoft.com. The set-up is non-volatile, so your RC1xx controller will resume the same operation after a power cycle.
  • Page 10: Ethernet Operation (Rc120)

    RC120 controller on your computer’s network and to connect to it. For more information on the use of GardasoftMaint and connecting your RC120, refer to the User Manual at www.gardasoft. com. Application note APP923, Troubleshooting Ethernet Problems is also available from the Gardasoft website.
  • Page 11: Using The Rc120'S Web Pages

    RC120, or by using its front panel buttons. You must use this method for setting the rating of a light with an RC100. The section below explains how to set the light rating using the front panel buttons.
  • Page 12: Safety Precautions

    Your light’s rating is set up. Safety precautions Read this before using the RC1xx. Always observe the following safety precautions. If in doubt, contact your distributor or Gardasoft Vision. The following symbols mean: Warning: Read instructions to understand possible hazards...
  • Page 13: Heat

    We recommend using a PSU that limits its output current to the appropriate rating of the controller by design, by setting the current limit on the supply (if possible), or through over current protection. The PSU should be approved to either www.gardasoft.com...
  • Page 14: General

    IEC 60950-1, IEC 60335-1, IEC 61010-1, IEC61558-1,-2,-16. The PSU may also be approved to equivalent or superior safety standards. Any energised conductors derived from mains electricity must also have » Safety Extra Low Voltage (SELV) output. At maximum ratings the temperature of the enclosure can exceed 65°C. »...
  • Page 15: Installation Guidance (Disclaimer)

    This information is for guidance only. Installers must perform their own risk assessment specific to each installation. While Gardasoft Vision Ltd has taken every care in the preparation of this advice, Gardasoft Vision Ltd accept no liability for damages of any kind except those required by law.
  • Page 16: Elektrik

    Elektrik Das RC1xx erzeugt Impulse mit hoher Energie. Achten Sie darauf, die Ausgänge korrekt anzuschließen und schützen Sie die Ausgangsverkabelung und Last gegen Kurzschlüsse. Beim Ausschalten bleibt Energie für etwa 15 Sekunden im RC1xx gespeichert. Das RC1xx verfügt über keine vollständige Nachlaufisolierung der Eingänge (einschließlich Trigger- und Kommunikationsports) und Ausgänge.
  • Page 17: Allgemein

    Weise verwendet wird, kann die Schutzvorrichtung des Geräts beeinträchtigt werden. Installationsanleitung (Haftungsausschluss) Diese Informationen dienen nur zur Orientierung. Installationstechniker müssen ihre eigene spezifische Risikobewertung für die jeweilige Installation durchführen. Auch wenn Gardasoft Vision Ltd diese Empfehlung mit größter Sorgfalt erstellt hat, übernehmen Gardasoft www.gardasoft.com...
  • Page 18 Sécurité Lisez ce document avant d’utiliser le RC1xx. Respectez les mesures de sécurité suivantes en toutes circonstances. En cas de doute, contactez votre distributeur ou Gardasoft Vision. Les symboles ci-dessous auront la signification suivante: Attention: Lisez les instructions pour comprendre quels sont les risques éventuels.
  • Page 19 Si le contrôleur est mal réglé ou en cas de panne, l’énergie fournie » par l’alimentation au contrôleur peut devenir directement connectée à n’importe quelle chaîne de sortie ou à toutes les chaînes de sortie. Vous devez prendre en compte ce paramètre durant l’installation et si nécessaire, fournir une protection adéquate. www.gardasoft.com...
  • Page 20 Ces informations sont seulement à titre indicatif. Les installateurs doivent effectuer leur propre évaluation des risques, pour chaque installation. Même si Gardasoft Vision Ltd a préparé minutieusement ces conseils, Gardasoft Vision Ltd décline toute responsabilité pour tout dommage, quel qu’il soit, à l’exception de ceux requis par la loi. La mise en péril volontaire ainsi que les actes de vandalisme ne sont pas couverts par le présent document et doivent être pris en compte par l’installateur.
  • Page 21 These pages are blank for your notes. www.gardasoft.com...
  • Page 23 www.gardasoft.com...
  • Page 24 Issue 004, September 2022 © Copyright 2022 Gardasoft Vision Ltd. Gardasoft Vision Ltd Trinity Court Buckingway Business Park Cambridge CB24 4UQ tel: +44 (0)1954 234970...

This manual is also suitable for:

Rc120

Table of Contents