GARDASOFT RT Series User Manual page 57

Led lighting controllers
Table of Contents

Advertisement

CH1,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,RT0.0us,IP1,FL0,CS0.
000A,RA0.000A
CH2,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,RT0.0us,IP2,FL0,CS0.
000A,RA0.000
WWW.STEMMER-IMAGING.COM
Save the settings to memory
AW
Once the settings are saved to memory they are retained when the
unit is switched off. If this is not done, changes to the settings are
volatile, and if the unit is switched off they revert to those in force
when the last AW command was issued.
Clear Configuration
CL
Clears the channel configuration and lighting ratings and sets all
channels to 50% continuous operation. The results of the VL, RS,
RW, RU, RT, RE, RP, TT, and AW commands are all cleared.
Show Configuration
ST
This command shows the operational parameters for all channels in
the controller. A typical output for an RT220 controller is:
Where:
CH
Channel number
MD
Mode: 0 = continuous, 1 = pulse, 2 = switched, 3 =
select
S
Brightness percentage settings:
1st setting used in all modes
2nd setting only used for select mode
DL
Pulse delay
PU
Pulse width
RT
Retrigger delay
IP
Input trigger (set using the RP command)
FL
Flags (set using the RE command)
CS
Rating of the light (after SafeSense has successfully
completed sensing the light)
RA
Rating of the light (set using the VL command).
RTxxx LED lighting controllers - User Manual
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents