3. Installation of the central control unit CMXR-C2
3.4.7

CAN interface [X4] (optional module CECX-F-CO)

As per CAN interface [X6] (see section 3.4.6).
3.4.8

Ethernet interface [X5] (optional module ETHERNET)

The central control unit is equipped at the factory with the optional module ETHERNET as
standard. This module provides an Ethernet connection for the Ethernet controller built
into the central control unit. An RJ-45 connection is available on the front panel for
programming. This means the device can be integrated into both a 10Mbit/s and a
100Mbit/s Ethernet.
RJ45 socket [X5]
Table 3.10 Pin allocation for the Ethernet interface [X5]
3.4.9

Ethernet interface [X7]

This interface provides an Ethernet connection for the Ethernet controller built into the
central control unit. An RJ-45 connection is available on the front panel for connecting to
an Ethernet network. This means the device can be integrated into both a 10Mbit/s and a
100Mbit/s Ethernet.
Festo GDCP-CMXR-C2-HW-EN 1002NH
Pin
1
2
3
4
5
6
7
8
Metal covering
Instructions on wiring can be found in section 3.3.
Signal
TD+
TD-
RD+
n.c.
n.c.
RD-
n.c.
n.c.
Shield
Explanation
Transmitted data+
Transmitted data
Received data+
Not connected
Not connected
Received data
Not connected
Not connected
Screening