Figure 4-2: Improper Installations of the Metal Standoffs
4.1
Mounting
For pipe clamp mounting, see clamp installation guide.
Procedure
1. On painted pipe-work, remove a singular patch of the coating about
1-in. (25 mm) diameter midway between the studs to allow
waveguides to contact pipe directly.
2. On straight pipes, ensure the studs are perpendicular to the sensor
contact point.
3. Apply Loctite
4. Record the installation location, sensor ID, MAC address of the
sensor, and power module serial number.
5. Examine the thermocouple and make sure it is protruding past the
end of the waveguide by about ⅛ in. (3mm) so that it will press onto
the pipe when the sensor is tightened as shown in
10
®
8009 anti-seize compound to the threads.
July 2019
Figure
4-3.