Handwheel Extended Interface (Only Universal Operator Panel) - Bosch Rexroth IndraControl VDP 80.1 Series Manual

Machine operator panel operator display
Table of Contents

Advertisement

46/61
Bosch Rexroth AG
Connections and Interfaces
6.7

Handwheel extended interface (only Universal operator panel)

Pin assignment
Signal connection diagram
Rexroth IndraControl VDP 80.1 Machine Operator Panel Operator Display
Fig.6-17:
Handwheel unit signal interfaces
Pin no.
04
03
02
01
Fig.6-18:
Pin assignment J20
Fig.6-19:
Signal connection diagram J20
DOK-SUPPL*-VDP*80.1***-PR03-EN-P
Assignment
GND
+5V
B (TTL)
A (TTL)

Advertisement

Table of Contents
loading

Table of Contents