DOK-SUPPL*-VDP*80.1***-PR03-EN-P
Rexroth IndraControl VDP 80.1 Machine Operator Panel Operator Display
Signal description
6.5

Interface Connection of Handwheel Unit

Pin assignment
Fig.6-9:
Extended IO interface (plug connector)
Check the total current!
The total current of all outputs cannot exceed 1 A. The current for
an individual output cannot exceed a maximum of 100 mA.
Check the polarity!
Verify the correct signal interface polarity as an incorrect connection
can result in fusing of the IO interface.
Check the correct position of the connection!
Signal description
DI-00 to DI-23
DO-00 to DO-15
COM+
COM-
J14
Bosch Rexroth AG
Connections and Interfaces
Description
Digital input 24 bits
Digital output 16 bits
Output 24V
0V