Electrical Installation For Servo Driven Models; Configuring The Sinamics S120 Drive; Initial Setup - Siemens SITRANS WW100 Operating Instructions Manual

Weighfeeders
Hide thumbs Also See for SITRANS WW100:
Table of Contents

Advertisement

4.2

Electrical installation for servo driven models

Note
● The frame of the weighfeeder needs to be grounded to ensure accurate signal processing
to the integrator.
● Refer to the electrical connection diagrams for several different S120 connection scenarios.
● The communication cable (green) and power cable (orange) must connect the servo motor
to the S120 to operate. The power (orange) cable has identifying markings on the shield to
ensure the connections match.
If the emergency stop is independent from the integrated safety feature on the control unit,
wire or jumper the digital inputs to complete the circuit.
4.2.1

Configuring the Sinamics S120 Drive

4.2.1.1

Initial setup

● New devices are shipped with factory default values in Non-Volatile MEMORY!
● P977 should be used with CAUTION when saving the Application Data to the Micro
● If the project has not been loaded in the Non-Volatile MEMORY, your application software
Important Command and Drive Data Set Notes
The following acronyms are referenced through the documentation required for the startup of
your Sinamics S120 Drive and WW100 Weighfeeder:
Acronym
CDS
DDS
The most common change for this application would be the maximum RPM (Belt Speed) of the
weighfeeder (P2000), and possibly the Reversal of Belt Direction (P1113), if required.
SITRANS WW100
Operating Instructions, 06/2018, A5E33560618-AC
WARNING
WARNING
Memory Card.
on the MICRO MEMORY CARD will be overwritten and LOST!
Full term
Definition
Command
Any parameters that may be changed or viewed and are associated with
Data Set
the Control Unit. This parameter set can be associated with any type of
control mode change such as enable signals, control functions, inputs and
outputs, etc.
Drive Data
Any parameters that may be changed or viewed and are associated with
Set
the Drive Unit. This parameter set effectively changes the characteristics
or dynamics of the motor, gearbox and belt speed of the WW100 Weigh‐
feeder.
4.2 Electrical installation for servo driven models
Installing
13

Advertisement

Table of Contents
loading