Removing/Reattaching Covers - YASKAWA GA800 Series Installation & Primary Operation

Ac drive for industrial applications
Hide thumbs Also See for GA800 Series:
Table of Contents

Advertisement

6 Mechanical Installation
Install Drives Side-by-Side
Users can install drive models 2004xB to 2082xB and 4002xB to 4044xB side-by-side.
To install other drive models adjacent to each other, you must keep 30 mm (1.2 in) between each drive.
For side-by-side installation of drive models 2004xB to 2082xB and 4002xB to 4044xB, make sure that there is
sufficient space as shown in
Derate the output current to align with the ambient temperature.
A - 50 mm (2 in) minimum
B - 30 mm (1.2 in) minimum on both
sides
Note:
• Align the tops of drives that have different dimensions to help when you replace cooling fans.
• Remove the top protective covers of all drives when mounting UL Type 1 enclosure drives side-by-side.
Figure 6.4 Enclosed Wall-Mounted Type (UL Type 1) Installed Side-by-Side

Removing/Reattaching Covers

This section gives information about how to remove and reattach the front cover and terminal cover for wiring and
inspection.
20
Figure
6.3. Set L8-35 = 1 [Installation Method Selection = Side-by-Side Mounting].
Figure 6.3 Installation Distances for Multiple Drives (Side-by-Side)
C - 2 mm (0.08 in) minimum between
each drive
D - 120 mm (4.7 in) minimum above
and below
YASKAWA TOEPC71061737B GA800 Drive Installation & Primary Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga80u seriesGa800

Table of Contents