SUN2000-(33KTL, 36KTL, 40KTL)-US
User Manual
Figure 5-42 Connecting wires to an RJ45 connector
(1) White-and-orange
(5) White-and-blue

5.6.3 Connecting RS485 Communications Cables Through a Pipe

Connecting Cables to the Terminal Block
Step 1 Install the pipe fittings.
1.
2.
Figure 5-43 Installing pipe fittings
Step 2 Route the communications cable through the conduit and then fittings of the pipe.
Issue 07 (2019-06-20)
Remove the locking cap and plug from the waterproof connector, and then remove the
waterproof connector.
Secure the pipe fittings to the chassis using the nut delivered with the pipe.
Copyright © Huawei Technologies Co., Ltd.
(2) Orange
(3) White-and-green
(6) Green
(7) White-and-brown
5 Connecting Cables
(4) Blue
(8) Brown
75