Electrical System
Maintenance

Electrical System Safety

Disconnect the battery or remove the spark-plug
wire before making any repairs. Disconnect the
negative terminal first and the positive terminal
last. Connect the positive terminal first and
negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

Service Interval: Every 100 hours
Always keep the battery clean and fully charged. Use
a paper towel to clean the battery case. If the battery
terminals are corroded, clean them with a solution of
four parts water and 1 part baking soda. Apply a light
coating of grease to the battery terminals to prevent
corrosion.
Voltage: 12 V
Removing the Battery
1.
Park the machine on a level surface, disengage
the PTO, and engage the parking brake.
2.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
3.
Remove the battery as shown in
Figure
49.
36
Figure 49
g030988