Priming the Fuel System (continued)
Do not use the engine-starter motor to crank the engine for fuel-system priming.
1. Ensure that fuel is in the fuel tank.
2. Perform the following steps to prime the filter and the lines to the high-pressure pump to
prevent wear or damage to the pump:
A. Cycle the ignition key to the O
B. Cycle the ignition key to the O
Note:
C. Cycle the key to the O
D. Inspect for leaks around the filter and hoses.
E. Start the engine and inspect for leaks.

Electrical System Maintenance

Inspecting the Electrical Cables

Inspect the electrical cables for damage, wear, loose fittings, weather deterioration, and
chemical deterioration.
Note:

Disconnecting the Battery

Battery electrolyte contains sulfuric acid, which is fatal if consumed and causes
severe burns.
• Do not drink electrolyte and avoid contact with skin, eyes, or clothing.
• Wear safety glasses and rubber gloves.
• Fill the battery where clean water is always available for flushing the skin.
1. Prepare the machine for maintenance.
2. Open the screen.
3464-486A
This allows the ECU to power down.
N
Make all necessary repairs before operating.
IMPORTANT
position for 15 to 20 seconds.
N
position for 30 to 40 seconds.
FF
position for 15 to 20 seconds.
DANGER