Ops Measurement Mode Menu; Dosage Menu; Si/Su Contacts Menu In Auto Mode; Control Port Menu - Applied Precision RS 2130 User Manual

Reference standard, standard meter of electrical power and energy
Table of Contents

Advertisement

OPS Meas/Test ->
Fout0 Config ...
MUT Constant
Sample Type
Int. Time
No. of Impulses
No. of Samples
Start
Stop
Mode
Time
Energy
Energy Unit
Contact SI Mode
Contact SU Mode
Contact SI Auto ... - entry to Contact SI Auto Mode Menu,
Contact SU Auto ... - entry to Contact SU Auto Mode Menu,
Contact SI State
Contact SU State

3.2.23 SI/SU Contacts Menu in Auto Mode

Start State
Start Delay
Stop State
Stop Delay
Signal OUTx
Signal Inx
Init values...
18

3.2.21 OPS Measurement Mode Menu

- start of OPS Measurement Mode screen
- Impulse Output Fout0 Menu (this functionality is dependent on Fout0 settings)
- parameter setting the constant of Meter Under Test
- parameter setting the mode of operation of OPS Measurement Mode.
Parameter value is 'Impulses' or 'Int. Time'.
- parameter setting the Integration Time for OPS Measurement Mode
- parameter setting the Number of Impulses for OPS Measurement Mode
- parameter setting the Number of Samples for OPS Measurement Mode

3.2.22 Dosage Menu

- dosage instant start
- dosage instant stop
- setting of dosage function in respect of a type – TIME, ACTIVE ENERGY,
REACTIVE ENERGY or APPARENT ENERGY, SQUARE VOLTAGE, SQUARE
CURRENT, OFF,
- setting the dosage lasting for time dosage, stated in seconds,
- setting the dosage amount for energy type dosage,
- setting the unit of energy when energy dosage is set,
- setting the SI contact into the state CONTACT OPEN or CONTACT CLOSED
or AUTO,
- setting the SU contact into the state CONTACT OPEN or CONTACT CLOSED
or AUTO,
- setting the SI contact state – open or closed,
- setting the SU contact state – open or closed,
- setting the SI/SU contact state for dosage start, there are three options –OPEN,
CLOSED and UNCHANGED,
- setting the delay of dosage starting, stated in seconds
- setting the SI/SU contact state for dosage stop, there are three options – OPEN,
CLOSED and UNCHANGED,
- setting the delay of dosage stopping, stated in seconds

3.2.24 Control Port Menu

- parameter of the direct control of the appropriate bite at the user control port
(value LOW corresponds to the logical 0, and value HIGH to logical 1,
respectively),
- parameter (which can be changed) setting the actual state of appropriate bites
at the user control port (value LOW corresponds to the logical 0, and value HIGH
to logical 1, respectively),
- control port initializing menu,
RS-UG91-EN
Reference Standard RS 2x30, RS 1x30
User's Guide