Logged data can be accessed remotely using this command:
SYSTem:HISTory:GET? {quantityCode}, {chnl}, {"timeString" }
Request for value from historical memory. Reply is historical value of defined quantity in defined channel
in defined time. First parameter is quantity code, second parameter is channel code (1, 2 and 3 for L1,
L2 and L3 channels) and third parameter is time string in "YYYY-MM-DD hh:mm:ss.xx" format.
Example: SYST:HIST:GET? 0,1,"2009-09-20 17:23:19.04730"
CODE
QUANTITY
0
Active Power
3
Reactive Power
6
Phase UI
Distortion of
9
Current
12
Apparent Energy
Example: "2009-09-20 17:23:19.04730".
Meanings of format parts:
YYYY ... year (4 digits)
MM ...... month (2 digits)
DD ....... day (2 digits)
40
Access to Logged Data and Statistics
List of quantities codes
CODE
1
4
7
10
Description of "YYYY-MM-DD hh:mm:ss.xx" format
hh ...... hour (2 digits)
mm .... minutes (2 digits)
ss ....... seconds (2 digits) xx ... fraction of second (max. 5 digits)
RS-UG91-EN
Reference Standard RS 2x30, RS 1x30
QUANTITY
Voltage
Apparent Power
Frequency
Active Energy
User's Guide
CODE
QUANTITY
2
Current
5
Phase UU
Distortion of
8
Voltage
11
Reactive Energy
www.appliedp.com