Fault Codes - Moffat turbofan E32SUBC Service Manual

Oven and proofer
Table of Contents

Advertisement

Fault codes

Message
Oven
Door open
Probe open error
Probe short error
Hi temp error
Proofer
Air probe open error
Air probe short error
Air Hi Temp error
Water probe open error
Water probe short error
Water Hi Temp error
Water low error
Humidity short error
Humidity open error
97% Actual humidity reading
Unit shuts down will not start
E32SUBC OVEN and PROOFER
Revision 3
Beep
Yes
Door open, Microswitch faulty
Yes
Oven temperature probe open circuit
Yes
Oven temperature probe short circuit
Yes
Oven temperature + 25
Yes
Proofer air temperature open circuit
Yes
Proofer air temperatures short circuit
Yes
Proofer temperature + 25
Yes
Proofer water temperature probe open circuit
Yes
Proofer water temperature probe short circuit
Yes
Water tank over temperature
Yes
Proofer water level low for more than 30 secs
Yes
Short in probe or between blue/yellow wires
Yes
Open circuit in humidity probe or
Short between white/yellow wires
Blue or Yellow wires disconnected
Yes
White wire disconnected.
Short circuit between Blue/ White wire to humidity probe
Blown controller fuse.
63
Fault
o
C
o
C
+ 25
12