6
Service Procedures
6.3.8

Door Handle

1) Open proofer door.
2) Remove four screws, remove handle.
3) Replace and re-assemble in reverse order.
Figure 6.3.8
6.3.9

Door Catch Magnet

1) Open proofer door.
2) Unscrew two screws securing magnet to

door.

3) Replace magnet catch and re-assemble in
reverse order.
Two screws
Figure 6.3.9
6.3.10 Door
1) Remove two screws from top of door holding
hinge to door.
E32SUBC OVEN and PROOFER
Revision 3
Top screws
Magnet
2) Slide door out at top and remove hinge pivot.
3) Lift door vertically off bottom hinge body (if
sticky loosen bottom hinge body two screws).
4) Remove bottom hinge pivot from door.
5) Fit hinge pivots (top and bottom) to new
door.
6) Re-assemble in reverse order.

6.3.11 Door Glass

1) Remove door as per steps one to three of
section 6.3.10.
2) Lay door face down on bench and remove
door seal.
Door Outer
Door Glass
14 Screws
3) Remove door inner (14 screws) and remove
glass.
4) Clean glass and replace in reverse order.
Ensure
silicone
displaced from door outer and door inner.
5) Reassemble and refit door in reverse order.
40
Hinge Body
Hinge pivot
two screws
Figure 6.3.10
Door Inner
Door Seal
Figure 6.3.11
seals
have
not
© Moffat Ltd, September 2009