Temperature Probe; Heating Contactor - Moffat turbofan E32SUBC Service Manual

Oven and proofer
Table of Contents

Advertisement

6
Service Procedures
6.2.4

Temperature probe

1) Remove R/H service panel (refer 6.1.2).
2) Cut cable ties securing thermostat probe
wires.
3) Undo the 2 screws on the flange which holds
the thermostat probe where the probe enters
the oven (inside oven).
4) Unplug probe from connector
5) Remove probe by drawing probe ,bracket and
wires out of oven.
6) Install the new probe in the reverse order.
Use high temperature (232°C / 450°F mini-
mum) RTV silicone sealant to seal probe hole
in oven liner.
Two screws
Figure 6.2.4a
Thermostat probe
Figure 6.2.4b
E32SUBC OVEN and PROOFER
Revision 3
6.2.5

Heating contactor

1) Remove the right hand service panel (refer
6.1.2).
2) Unclip contactor from the gear plate.
3) Clip new contactor onto gear plate.
4) Transfer wires from old contactor to new con-
tactor, ensuring all wires are in their correct
positions.
34
Contactor
Figure 6.2.5
© Moffat Ltd, September 2009