Replacement-Proofer; Temperature Probe; Humidity Probe; Water Temperature Probe - Moffat turbofan E32SUBC Service Manual

Oven and proofer
Table of Contents

Advertisement

6
Service Procedures
6.3
Replacement—Proofer
6.3.1

Temperature probe

1) Remove RHS service panel (refer 6.1.4) and
unplug probe.
2) With door open, remove right hand side rack.
Undo probe support bracket screws (4) and
remove bracket from inside service area.
4 screws
Figure 6.3.1a
Support bracket
Figure 6.3.1b
3) Remove old temperature probe and fit new pr
4) Re-assemble in reverse order.
6.3.2
Humidity Temperature probe
1) Remove RHS service panel (refer 6.1.4) and
unplug probe.
2) With door open, remove right hand side rack.
Undo probe support bracket screws (2) and
remove bracket from inside oven.

Humidity probe

Figure 6.3.2
E32SUBC OVEN and PROOFER
Revision 3
3) Re-assemble in reverse order.
4) Ensure hole in proofer wall through which the
temperature probe wires pass is re-sealed
with RTV silicone sealant.
6.3.3

Water Temperature probe

1) Remove RHS service panel (refer 6.1.4) and
unplug probe.
2) Undo securing screw and nut from inside
proofer
Screw
3)
Remove bracket from inside service area.
4)
Re-assemble in reverse order.
6.3.4

Dry Element

1) Remove RH side panel (refer 6.1.4), remove
wires from element terminals, noting position.
2) With door open, remove right hand side rack.
3) Undo the two screws holding the element
cover and remove cover.
4) Unscrew the element from RH side (outside)
of proofer. Pull element carefully to remove
from inside of proofer.
38
Figure 6.3.2
Figure 6.3.4a
© Moffat Ltd, September 2009