Moffat turbofan E32SUBC Service Manual page 17

Oven and proofer
Table of Contents

Advertisement

3.3.4
System (con't)
System Beeper Volume Settings. (cont'd)
Press either 'Left' or 'Right' keys to scroll through the Beeper Volume settings and press
the Programming Key 'P' to save the change.
The Humidity Offset Setting screen will display
Press either 'Left' or 'Right' keys to scroll through the Humidity Offset settings and
press the Programming Key 'P' to save the change
The Humidity Sampling Interval Setting screen will display.
Press either 'Left' or 'Right' keys to scroll through the Humidity Sampling Interval set-
tings and press the Programming Key 'P' to save the change
The Water Tank Maximum Temperature Setting screen will display.
Press either 'Left' or 'Right' keys to scroll through the Water Tank Maximum Tempera-
ture settings and press the Programming Key 'P' to save the change
The Water Tank Minimum Temperature Setting screen will display
Press either 'Left' or 'Right' keys to scroll through the Water Tank Minimum Tempera-
ture adjustment settings to the temperature required and press the Programming Key
'P' to save the change and return to the Service Menu.
Scroll down to the 'Exit' menu and press the Programming Key 'P' to exit the Service
Menu. The programming light 'Prog' will go out.
E32SUBC OVEN and PROOFER
Revision 3
Humidity Offset Settings.
Range - -30% to + 30%.
Factory Default = +2%
Humidity Sampling Interval Settings.
Range - 0 to 120 Secs.
Factory Default = 30
Water Tank Maximum Temperature Settings.
o
Range - 35 to 50
C.
Factory Default = 46
Water Tank Minimum Temperature Settings.
o
Range - 35 to 50
C.
Factory Default = 39
13
o
C
o
C
3
Operation
© Moffat Ltd, September 2009