Moffat Turbofan P8M series Installation And Operation Manual

Moffat Turbofan P8M series Installation And Operation Manual

P series proofer/holding cabinets
Hide thumbs Also See for Turbofan P8M series:

Advertisement

Quick Links

PSERIES
P 8 M / P 1 0 M / P 1 2 M
S e r i e s
P r o o f e r / H o l d i n g C a b i n e t s
( M a n u a l O p e r a t i o n )
I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
234277-10

Advertisement

Table of Contents
loading

Summary of Contents for Moffat Turbofan P8M series

  • Page 1 PSERIES P 8 M / P 1 0 M / P 1 2 M S e r i e s P r o o f e r / H o l d i n g C a b i n e t s ( M a n u a l O p e r a t i o n ) I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l 234277-10...
  • Page 2 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3833 Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281...
  • Page 3: Table Of Contents

    P8M/P10M/P12M Turbofan Proofer / Holding Cabinets. Model Numbers Covered in this Manual - Turbofan Proofer / Holding Cabinet - 8 Tray. P10M - Turbofan Proofer / Holding Cabinet - 10 Tray. P12M - Turbofan Proofer / Holding Cabinet - 12 Tray.
  • Page 4: Introduction

    Cabinet, contact your TURBOFAN dealer promptly. In Dealer: many cases a phone call could answer your question. Should you contact your TURBOFAN dealer on any matter Service Provider: concerning this proofer / holding cabinet, please have the information provided opposite, readily available.
  • Page 5: Specifications

    Specifications P8M Proofer / Holding Cabinet P8M Specifications Table:- 110-120V, 1P+N+E, 60HZ, 1.45 kW Power Ratings 220-240V, 1P+N+E, 50/60HZ, 1.50 kW 8, 18” x 26” / 460 x 660, Full Size Sheet Pan Capacity. Tray Capacity 16, 18” x 13” / 460 x 330, Half Size Sheet Pan Capacity. 8, 600 x 400mm Tray Capacity (Optional Kit).
  • Page 6 Specifications P10M Proofer / Holding Cabinet P10M Specifications Table:- 110-120V, 1P+N+E, 60HZ, 1.45 kW Power Ratings 220-240V, 1P+N+E, 50/60HZ, 1.50 kW 10, 1/1 GN Gastronorm Pan Capacity. Tray Capacity 10, 20” x 12”, Hotel Steam Pan Capacity. 10, 18” x 13” Half Size Sheet Pan Capacity. Tray Spacing 74mm / 2 ”...
  • Page 7 Specifications P12M Proofer / Holding Cabinet P12M Specifications Table:- 110-120V, 1P+N+E, 60HZ, 1.95 kW Power Ratings 220-240V, 1P+N+E, 50/60HZ, 1.90 kW 12, 18” x 26” / 460 x 660, Full Size Sheet Pan Capacity. Tray Capacity 24, 18” x 13” / 460 x 330, Half Size Sheet Pan Capacity. 12, 600 x 400mm Tray Capacity (Optional Kit).
  • Page 8: Installation

    It is most important that this proofer / holding cabinet is installed correctly and that the operation is correct before use.  If you have any questions regarding the proper installation and / or operation of this proofer / holding cabinet , please contact your local Turbofan distributor. Clearances Unpacking To ensure correct ventilation for the motor and controls, 1.
  • Page 9: Water Connection

    Installation Water Connection 1. A cold water supply should be connected to the water inlet located on the rear right hand side of the unit. 2. Connect to the water supply. Water Connection - Max Inlet Pressure 80psi / 550kPa. 3.
  • Page 10: Operation

    Operation Operation Guide  Turbofan Proofer / Holding Cabinets have been designed to provide simple operation.  This Proofer / Holding Cabinet is intended for use in a commercial kitchen and must only be put to the use for which it was intended, i.e.
  • Page 11: Operating In 'Proof' Mode

    Operation Operating in ‘Proof’ Mode Operating in ‘Hold’ Mode Caution Caution Take care when opening proofer Some parts of this proofer / holding cabinet holding cabinet door during the Proofing will become HOT during the Hold Mode and Mode. Let hot air and steam escape before could cause burns if touched accidentally.
  • Page 12: Cleaning And Maintenance

    Cleaning and Maintenance Cleaning Guidelines Side Racks - P8 / P12 a. To remove side racks Upper Rack Keyhole for cleaning, take hold Caution and Hanger Stud of top and bottom of Always turn ‘Off’ the electrical power supply rack and lift front of mains supply before...
  • Page 13 Cleaning and Maintenance Water Tank Door It is recommended that this procedure is carried out a. Wash door with warm water and a mild detergent once a week. Frequency of cleaning the element solution using a soft sponge in straight lines up and may be increased or decreased depending on the down inner and outer surfaces of door.
  • Page 14: Periodic Maintenance

    Cleaning and Maintenance Lamp Glass - P8 / P12 Periodic Maintenance NOTE: All maintenance operations should only be The P8 and P12 Proofer / carried out by a qualified service person. Holding Cabinets are fitted with 2 halogen Controls and mechanical parts should be checked and lamps.
  • Page 15: Fault Finding

    Fault Finding This section provides a reference to the more common You may encounter a problem not covered in this section, problems that may occur during the operation of your please contact your service provider who will require the proofer / holding cabinet. This fault finding guide is following information:- intended to help you correct, or at least accurately diagnose problems with your proofer / holding cabinet.
  • Page 16: Electrical Schematic

    Electrical Schematic Electrical Schematic P8M / P10 / P12M Proofer Holding Cabinets.
  • Page 17: Replacement Parts List

    The instructions supplied with the parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service provider or Turbofan Dealer. When ordering replacement parts, please quote the part number and the description as listed below. If the part required is not listed below, request the part by description and quote model number and serial number which is shown on the Technical Data Plate.
  • Page 18: Appendix 1 - Proofer Door Reversal (P8 / P12 Only)

    Appendix 1 - Proofer Door Reversal Reversing Proofer Door (P8 / P12 Only) NOTE:  Refit all screw fasteners using a low-mid strength thread locking adhesive unless otherwise stated.  Door reversal should only be carried out by a suitably competent person. 1.