Proline Prosonic Flow 91W
5.4

Group Sensor Setup

Picklist SENSOR SETUP:
• SETUP
• LIQUID
• PIPE DATA
• LINER
• CONFIG. CHANEL
• POS. SENSOR
• QUIT
SETUP: LIQUID TEMPERATURE  SOUND VEL. LIQUID 
PIPE MATERIAL SOUND VEL.PIPE CIRCUMFERENCE 
PIPE DIAMETER WALL THICKNESS  LINER MATERIAL 
SOUND VEL. LINER LINER THICKNESS SENSOR TYPE 
SENSOR CONFIG. CABLE LENGTH  POS.SENSOR/WIRE
LENGTH SENSOR DISTANCE 
LIQUID: LIQUID TEMPERATURE SOUND VEL. LIQUID
PIPE DATA: PIPE MATERIAL SOUND VEL.PIPE CIRCUMFERENCE 
PIPE DIAMETER WALL THICKNESS
LINER: LINER MATERIAL SOUND VEL. LINER LINER THICKNESS
CONFIG. CHANNEL:SENSOR TYPE SENSOR CONFIG. CABLE LENGTH
POS.SENSOR:POS.SENSOR/WIRE LENGTH SENSOR DISTANCE 
The following information is required for a successful setup:
• Sound velocity of the liquid
• Operating temperature
• Pipe circumference or pipe outer diameter
• Sound velocity of the pipe material
• Wall thickness
• Sound velocity of the lining material (if present)
• Thickness of the lining (if present)
• Sensor type
• Sensor arrangement (direct or reflection mode)
• Length of the sensor cable
5.5

Troubleshooting

A complete description of all the error messages is provided in the Operating Instructions on the
CD-ROM.
!
Note!
The output signals (e.g. pulse, frequency) of the measuring device must correspond to the
higher-order controller.