Resetting the whole system
1
From the top menu, select Setup/Diag >System
>Initialize.
The Initialize menu appears.
2
Press [Reset].
The popup window closes, and a confirmation
message appears, prompting whether or not to reset.
3
Press [Yes] in the dialog box.
This resets the system.
To cancel the reset
Press [No] in the dialog box.
Initializing memory
1
Carry out step 1 in the previous item, "Resetting the
whole system."
2
Press [All Clear].
The popup window closes, and a confirmation
message appears, prompting whether or not to carry
out the memory initialization.
3
Press [Yes] in the dialog box.
This initializes memory, and resets the system.
To cancel memory initialization
Press [No] in the dialog box.
Input Signal Setup (Input/Output
Menu)
Use the Input/Output menu to carry out setup relating to
processor primary input signals.
You can make the following settings.
Phase: Adjust the phase of the primary input signals.
Through mode: For each primary input, select whether
the through mode is on or off. The through mode is a
166
Other Settings
mode in which the sync signal included in an output
signal is not replaced by an internally generated sync
signal, but is left unchanged.
Video process: Adjusts the input signal luminance and
hue.
Carrying out phase adjustments and
through mode setting
1
From the top menu, select Setup/Diag >Input/Output
>Input Adjust.
The Input Adjust menu appears. The status area shows
the input number, signal phase, and through mode
setting.
2
Select the input number for which you want to make
the setting.
• Press directry on the list in the status area.
• Use the arrow buttons to scroll the reverse video
cursor.
• Turn the knob.
Knob
Description
1 (Input)
Input number selection
a) Values 9 to 16 are only valid when the MKS-2110M (option) is
installed.
The selected input number appears in reverse video.
3
To adjust the phase, press [Input Phase], and turn the
knobs to adjust the parameters.
Knob
Description
2 (Input Phase)
Phase
4
To carry out the through mode setting, press [Thru
Mode], toggling it between Enable and Disable.
Enable: Enable the through mode.
Disable: Disable the through mode.
Setting
values
a)
1 to 16
Setting values
–16 to +16