The popup window in the Startup Mode menu closes,
and a confirmation message appears, prompting
whether or not to change the mode.
3
Press [Yes] in the dialog box.
This changes the mode.
To cancel changing the mode
Press [No] in the dialog box.
Selecting custom mode mode for starting
up after powering on
To set setup to custom mode
1
Carry out step 1 in the previous item, "Selecting
resume mode for starting up after powering on."
2
If [Resume] is On, set it to Off.
3
Press [Setup].
A popup window appears.
4
Press [User] or [Factory].
The popup window closes, and a confirmation
message appears, prompting whether or not to change
the mode.
5
Press [Yes] in the dialog box.
This changes the mode.
To cancel changing the mode
Press [No] in the dialog box.
To set initial status to custom mode
In step 2 of the above procedure, "To set setup to custom
mode," in place of [Setup], press [Init Status].
The remainder of the operation is the same.
Output Signal Assignment (Output
Assign Menu)
Assign output signals to each output port of the processor.
1
From the top menu, select Setup/Diag >Input/Output
>Output Assign.
The Output Assign menu appears. The status area
shows output port numbers and the output signals
assigned to each port.
2
Select the output port number for which you want to
make the setting.
• Press directry on the list in the status area.
• Use the arrow buttons to scroll the reverse video
cursor.
• Turn the knob.
Knob
Description
1 (No)
Output port number selection
a) Values 5 to 8 are only valid when the MKS-2110M (option) is
installed.
The selected output port number appears in reverse
video.
3
Press [Out Assign].
A popup window appears. The assignable output
signals are shown.
Assignable output signals
• M/E PGM (M/E program signal)
• M/E PVW (M/E preview signal)
• M/E Key PVW (M/E key preview signal), M/E Key
Out (M/E key output signal), or M/E PGM Clean
(M/E program clean signal): The display varies
depending on the setting of [M/E Key PVW] in the
Output Assign menu.
Setting
values
a)
1 to 8