Status and error codes

This section provides a key to the five-letter status and error codes used in the
Highlander Wash.
All states except HOT are sticky, meaning they are shown in the fixture's control panel
display until the next power cycle or the next motor reset.
Motor errors are usually issued by a failed self-test (motor not connected, PCBA not
connected) or position feedback errors during a reset (motors with position feedback
only).
Code
Notes
Overtemperature condition detected. Lamp housing temperature
sensor exceeded threshold, or temperature switch tripped. Lamp will
* HEAT
be powered off and cooldown sequence will be initiated.
Lamp failed to strike. Possible causes: lamp was too hot, no lamp
installed, or ELD (Electronic Lamp Detector) connector is missing. In
* HOT
addition, when you douse the lamp the fixture will display a HOT code
until it is cool enough to power down the fixture.
Focus error
* FOCER
Zoom error
* ZOOER
Color Wheel 1 error
* CW1ER
Color Wheel 2 error
* CW2ER
Cyan, Magenta, Yellow or CTO error
* CMYER
Error on one or more framing blades or on framing rotation
* FRAER
Pan error
* PANER
Tilt error
* TILER
Dimmer error
* DIMER
Shutter error
* SHUER
Issued if lamp is doused unexpectedly or if communication with the
* ELDER
ELD is lost / not possible
Communication with onboard flash memory is not possible, or written
data in flash memory cannot be read properly (inability to read flash
* MEMER
data can be due to end of flash memory lifetime)
Fan error
* FANER
24
Highlander Wash
User Manual