Advertisement

Quick Links

1200 Basic & 575 Basic
Instruction Manual
From Version 1.0
email: glplight@aol.com
Internet: http://www.GLP.de

Advertisement

Table of Contents
loading

Summary of Contents for GLP Patend Light 1200 Series

  • Page 1 1200 Basic & 575 Basic Instruction Manual From Version 1.0 email: glplight@aol.com Internet: http://www.GLP.de...
  • Page 2 German Light Production (V2.1)
  • Page 3: Table Of Contents

    Contents Introduction ......................4 1.1 S ....................5 AFETY ULES Installation .......................6 2.1 M ......................6 OUNTING 2.1.1 Clamps (Hooks) ..................6 2.1.2 Mountingplate..................6 2.2 S 1200 ................6 ECURE THE ATEND IGHT 2.3 C .....................7 ONNECTORS 2.3.1 AC Connectors..................7 2.3.2 DMX .......................7 2.4 F ........................7 The Menu Field ......................8 3.1 A...
  • Page 4 Change the Gobos ....................16 6.1 S ....................16 AFETY ULES 6.2 H ................16 OW TO CHANGE THE OBOS Maintenance the PATEND-LIGHT 1200/575 BASIC..........17 7.1 M ................17 IRROR AND PTICAL YSTEM 7.1.1 Cleaning the inside Mirror and the outside Optical System ....18 7.1.2 Cleaning the outside Optical System ...........18 7.2 V ..................19...
  • Page 5: Introduction

    Introduction Illustration 1-1 German Light Production (V2.1)
  • Page 6: Safety Rules

    Illustration 1-2 1.1 Safety Rules C is a high-tech product. To guarantee a smooth operation, it is necessary to keep following rules. 1. Make sure that head and mirror of the C , can rotate without any mechanical problems and that all fan openings are clean and not blocked by anything.
  • Page 7: Installation

    6. To allow a secure operation, follow also the Installation guide described in chapter 2. Operating the C without suited safety aids like safety cables or clamps/hooks can increase the risk of an accident. 7. The installation should be done by qualified staff only. You need to pay attention to the common rules of technology that are not explicit mentioned in this manual.
  • Page 8: Connectors

    2.3 Connectors 2.3.1 AC Connectors 230 Volt, 50 Hz / 10AT 2.3.2 DMX 512 Standard input/output Please see printing on the case for the right Pin usage! [+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 3 The DMX- Address starts at the C at the DMX- Address [000].
  • Page 9: The Menu Field

    3 The Menu Field 3.1 Adjust the DMX-Address Right after turning on the C you can see the current DMX-Address. Choose this as follows. Select the DMX-Level and press the menu key. This level is called on automatically after turning on the Select the figure you want to adjust by pressing the cursor key.
  • Page 10: Read Out The Running Time Of Lamp And Unit

    3.2 Read out the Running Time of Lamp and Unit Select the time level by pressing the menu key twice. Select the requested time by pressing the cursor key, 3.2.1 Lamp Time 1 The current lamp time is shown alternating with LA 1. 3.2.2 Lamp Time 2 The total lamp time is shown alternating with LA 2.
  • Page 11: The Test Level

    3.4 The Test Level The Test Level makes a function test or a selftest procedure possible. 3.4.1 Selftest Procedure Select the requested test level by pressing the Cursor key. Start the Selftest program by pressing the Data+ key. The lamp can be started by pressing the Data+ and Data- keys for 5 seconds at the same time.
  • Page 12: Channel Selection ( Overview Table )

    4 Channel selection ( Overview table ) Channel Description DMX-Value Hex-Value Value % 1) Head Headposition, Low Byte (0 -1,41 0 - 255 0 - FF 0 – 100% 2) Head Headposition, High Byte (0 -360 0 - 255 0 - FF 0 –...
  • Page 13 Channel Description DMX-Value Hex-Value Value % bi (turquiose – orange) 65 - 69 41 - 45 25 – 26% color 8 (orange) 70 - 74 46 - 4A 27 – 28% bi (orange – cyan) 75 - 79 4B - 4F 29 –...
  • Page 14 Channel Description DMX-Value Hex-Value Value % Gobo 5 40 – 49 28 - 31 16 – 19% Gobo 6 50 – 127 32 - 7F 20 – 50% rotation cw slow . fast 128 – 191 80 - BF 51 – 74% stop rotation ccw slow –...
  • Page 15: Change The Lamp

    5 Change the Lamp For a hassle free change of the Light bulb, it is absolutely necessary to follow all descriptions in this chapter step by step. 5.1 Safety Rules • Unplug AC power connection • Allow to cool (min. 30 minutes) •...
  • Page 16: How To Change The Lamp

    5.2 How to change the lamp Please look also Illustration 1-1 and 5-1/2. 1. Unscrew screws on the head with 8mm wrench. 2. Press the two safety levers at the same time and lift carefully the head plate. 3. Remove Sub-D socket by pressing the safety clips. Hang out the safety loop and lift the head plate cautiously.
  • Page 17: Change The Gobos

    6 Change the Gobos The PATEND-LIGHT 1200/575 BASIC is fitted with standard Gobos (37,5 mm). To change one of these it is necessary to open the PATEND-LIGHT 1200/575 BASIC and to remove the optical system. 6.1 Safety Rules • Unplug AC power connection •...
  • Page 18: Maintenance The Patend-Light 1200/575 Basic

    7 Maintenance the PATEND-LIGHT 1200/575 BASIC The cleaning of the inner optical System, color filters, color correction filter and lenses should be done by qualified person only! Contact your local GLP Dealer for details. Use no strong detergents, acid etc. for cleaning the case.
  • Page 19: Cleaning The Inside Mirror And The Outside Optical System

    7.1.1 Cleaning the inside Mirror and the outside Optical System Illustration 7-1 • Open the screws • Remove the Mirror Blind 7.1.2 Cleaning the outside Optical System Illustration 7-2 German Light Production (V2.1)
  • Page 20: Ventilation System

    1. Unscrew screws on the head with 8mm wrench. 2. Press the two safety levers at the same time and lift carefully the head plate. 3. Remove Sub-D socket by pressing the safety clips. Hang out the safety loop and lift the head plate cautiously. 4.
  • Page 21: Technical Data /Overview

    8 Technical Data /Overview • Supply Data 230V/10AT • 1200 HMI W/S (110.000Lm) or 575 HMI (49.000 Lm) Lamp, bilateral based, with 750h Lamp Life • Capacitor compensation • DMX 512 Standard • weight 39 kg (1200 Basic), 34 kg (575 Basic) •...
  • Page 22 German Light Production (V2.1)

This manual is also suitable for:

Patend light 1200 basicPatend light 575 basic

Table of Contents