ES---8 Integral
Air Compressor/Dryer & Filter
OPERATOR'S
MANUAL AND

PARTS LIST

KEEP FOR
FUTURE
REFERENCE
Part Number 02250061--- 282
eSullair Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Sullair ES-8

  • Page 1: Parts List

    ES---8 Integral Air Compressor/Dryer & Filter OPERATOR’S MANUAL AND PARTS LIST KEEP FOR FUTURE REFERENCE Part Number 02250061--- 282 eSullair Corporation...
  • Page 2 SEMINAR TRAINING Sullair Air Care Seminars are 2---day courses that provide hands---on instruction in the proper operation, maintenance and service of Sullair Dryers and Filters. Seminars are presented at regular intervals throughout the year at a dedicated training facility at Sullair’s corporate headquarters in Michigan City, Indiana.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Section 1 SAFETY 1.1 GENERAL 1.2 PERSONAL PROTECTIVE EQUIPMENT 1.3 PRESSURE 1.4 FIRE AND EXPLOSION 1.5 MOVING PARTS 1.6 HOT SURFACES, SHARP EDGES AND SHARP CORNERS 1.7 TOXIC AND IRRITATING SUBSTANCES 1.8 ELECTRICAL SHOCK 1.9 LIFTING 1.10 ENTRAPMENT Section 2 DESCRIPTION 2.1 INTRODUCTION...
  • Page 4 TABLE OF CONTENTS (CONTINUED) Section 5 COMPRESSOR SYSTEMS (cont.) 5.2 COMPRESSOR SYSTEM DESCRIPTION OF COMPONENTS 5.3 COMPRESSOR SYSTEM, FUNCTIONAL DESCRIPTION 5.4 COMPRESSOR COOLING SYSTEM, FUNCTIONAL DESCRIPTION 5.5 AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION 5.6 CONTROL SYSTEM, FUNCTIONAL DESCRIPTION Section 6 SUPERVISOR II 6.1 INTRODUCTION 6.2 KEYPAD 6.3 STATUS DISPLAYS...
  • Page 5 TABLE OF CONTENTS (CONTINUED) Section 9 COMPRESSOR MAINTENANCE AND TROUBLESHOOTING 9.1 INTRODUCTION 9.2 DAILY OPERATION 9.3 MOTOR BEARING LUBRICATION 9.4 FLUID FILTER MAINTENANCE 9.5 COOLER MAINTENANCE 9.6 PARTS REPLACEMENT AND ADJUSTMENT PROCEDURES 9.7 TROUBLESHOOTING INTRODUCTION (COMPRESSOR) 9.8 TROUBLESHOOTING--- COMPRESSOR 9.9 CALIBRATION 9.10 MAINTENANCE RECORD Section 10 DRYER...
  • Page 6 TABLE OF CONTENTS (CONTINUED) Section 11 ILLUSTRATIONS AND PARTS LIST (cont.) 11.6 COMPRESSOR COOLER SYSTEM AND PARTS (ES--- 8) 11.7 REFRIGERANT SYSTEM (DRYER) 11.8 AIR SYSTEM (DRYER) 11.9 FRAME, CANOPY AND PARTS 11.10 DECAL GROUP 11.11 WIRING DIAGRAM--- FULL VOLTAGE (STANDARD) 11.12 WIRING DIAGRAM--- FULL VOLTAGE (DELUXE)
  • Page 7 SAFETY 1.1 GENERAL A. Install an appropriate flow ---limiting valve be- Sullair Corporation and its subsidiaries design and tween the service air outlet and the shut ---off manufacture all of their products so they can be op- (throttle) valve, either at the compressor or at any erated safely.
  • Page 8: Fire And Explosion

    Section 1 SAFETY the outside of the structure or to an area of non---ex- wise degraded insulation, or terminals that are posure. worn, discolored or corroded. Keep all terminals and pressure connectors clean and tight. M. DO NOT engage in horseplay with air hose as se- F.
  • Page 9 Section 1 SAFETY Table 1 POTENTIAL HAZARDS OF FLUOROCARBON REFRIGERANTS WARNING Dryers contain HCFC. This substance harms the public health and environment by destroying the ozone in the upper atmosphere. CONDITION POTENTIAL HAZARD SAFEGUARD VAPORS MAY DECOMPOSE IN Inhalation of Toxic Good ventilation.
  • Page 10: Toxic And Irritating Substances

    Section 1 SAFETY C. Wear personal protective equipment including 1.8 ELECTRICAL SHOCK gloves and head covering when working in, on or A. This compressor/dryer should be installed and around the compressor/dryer. maintained in full compliance with all applicable Federal, State and Local codes, standards and reg- D.
  • Page 11: Entrapment

    Section 1 SAFETY G. DO NOT lift compressor/dryer by motor---lifting N. Forklift no higher than necessary to clear ob- eye. stacles at floor level and transport and corner at minimum practical speeds. H. Keep all personnel out from under and away from the compressor/dryer whenever it is suspended.
  • Page 12 NOTES...
  • Page 13: Introduction

    1. Pa rts can be ordered from t he fect at the time of printing. The manufacturer re- nearest Sullair representative. If for any reason parts serves the right to change design and specifications cannot be obtained in this manner, contact the fac- without notice and without incurring obligations.
  • Page 14: Refrigerant Circuit, Functional Description

    Section 2 DESCRIPTION 2.3 REFRIGERANT CIRCUIT, FUNCTIONAL DE- evaporator, where it turns back to its vapor state and SCRIPTION routes back to the compressor inlet port. The ES---8 Integral Dryer cools the process air by To prevent feeding the compressor with liquid R---22 the use of a closed---loop vapor compression refrig- or evaporator icing during low heat load operation eration cycle.
  • Page 15: Compressed Air Circuit, Functional Description

    Section 2 DESCRIPTION 2.4 COMPRESSED AIR CIRCUIT, FUNCTIONAL DE- 2.5 REFRIGERANT SYSTEM COMPONENT, FUNC- SCRIPTION TIONAL DESCRIPTION The compressed air drying circuit uses an air---to--- The refrigerant compressor compresses low pres- air heat exchanger which acts as a precooler/re--- sure refrigerant gas into high pressure refrigerant heater, and an air---to---refrigerant heat exchanger gas.
  • Page 16 NOTES...
  • Page 17: Specifications

    Section 3 SPECIFICATIONS 3.1 SPECIFICATIONS -- ES-- 8 INTEGRATED COMPRESSOR/DRYER Figure 3 ---1 ES ---8 Compressor 50 Hz /MIN LENGTH WIDTH HEIGHT WEIGHT dBA (I) MODEL (MM) (MM) (MM) (KG) w/ Encls. w/o Encls. 1.62 1321 70/80 15HH 1.34 1321 70/80 15XH 1.02...
  • Page 18 A --- 115/1/60 B --- 230/1/60 FLUID FILTER Type: Spin on, Sullair Proprietary Micron: 23 Microns Abs. Internal Bypass Valve Set at 25 psig (1.7 bar) FLUID SEPARATOR ELEMENT Type: Push In Cartridge, Sullair Proprietary Efficiency at Maximum Capacity: 5PPM Maximum...
  • Page 19: Lubrication Guide

    Sullair for recommendation. (I) Plastic Pipe Institute, Recommendation B, Adopted January 19, 1972. Sullair encourages the user to participate in a fluid analysis program. This could result in a fluid change Maintenance of all other components is still recom- interval that is different from those stated in this mended as indicated in the Operator’s Manual.
  • Page 20 NOTES...
  • Page 21: General

    Sullair representative or the factory of the (I) Plastic Pipe Institute, Recommendation B, nature of the damage. The carrier is legally respon- Adopted January 19, 1972.
  • Page 22: Electrical Preparation

    OSHA, National Electrical Code, and/or any other applicable State, Federal and local electrical codes NOTE concerning isolation switches, fused disconnects, etc. Sullair provides a wiring diagram for use by the Grounding of the frame is required. installer. Refer to wiring diagrams in Section 11.
  • Page 23: Introduction

    Compared with other types of compressor units, pulse---free air compression to meet your needs. the Sullair rotary screw is unique in mechanical reli- With a Sullair compressor there will be no mainte- ability, with “no wear” and “no inspection” required nance or internal inspection of the compressor.
  • Page 24: Compressor Cooling System, Functional Description

    Section 5 COMPRESSOR SYSTEMS Figure 5 ---2 Encapsulated Compressor System The air/fluid mixture discharges directly into the fluid separation takes place due to a reduction of fluid management system. flow speed coupled with a change of direction of the flow within the sump housing. Then the com- The fluid cooler bypass valve helps assure proper pressed air reaches the separator where the finest cooling by directing the fluid to the fluid cooler...
  • Page 25: Air Inlet System, Functional Description

    Section 5 COMPRESSOR SYSTEMS cooling of air on units with air aftercoolers. MODULATING MODE -- 100 TO 110 PSIG (6.9 TO 7.6 bar) If less than the rated capacity of compressed air is 5.5 AIR INLET SYSTEM, FUNCTIONAL being used, the service line pressure will rise above SCRIPTION 100 psig (6.9 bar).
  • Page 26 NOTES...
  • Page 27: Introduction

    Section 6 SUPERVISOR II 6.1 INTRODUCTION change displays and in parameter setup mode to increment a value. Refer t o Figure 6 --- 1. The Supervisor II has a tw o line display to show temperature, pressure and sta- tus. It has a keypad for operating the compressor, programming the control points and selecting dis- plays.
  • Page 28: Lamp Indicators

    Section 6 SUPERVISOR II If there are alarms active they will alternately be S Next to last fault log. This shows the fault shown with the default display. The machine status on the first line and the run hours when the will be displayed for two seconds, then the alarms fault occurred.
  • Page 29 Section 6 SUPERVISOR II Figure 6 ---1 Supervisor II Panel...
  • Page 30 NOTES...
  • Page 31: General

    Section 7 COMPRESSOR OPERATION 7.1 GENERAL cally start after power up. While Sullair has built into this compressor a com- prehensive array of controls and indicators to as- RST TIME sure you that it is operating properly, you will want...
  • Page 32: Operating The Compressor

    Section 7 COMPRESSOR OPERATION Protocol Manual (See Recommended Manual for details. Spare Parts List) for details about these modes. SEQ HRS 1000 SEQUENCE 7.4 OPERATING THE COMPRESSOR HOURS Before operating the compressor the operating pa- rameters must be setup. See the previous section S Drain interval --- The time between actua- on operating parameter setup.
  • Page 33: Purpose Of Controls

    Section 7 COMPRESSOR OPERATION timer will start timing. When the timer expires the enabled (start/stop, load/unload, master/ machine will start. local). SEQUENCING MODES S SLAVE --- Will respond to all messages, The following is a brief description of sequencing but will not start or load unless command- modes.
  • Page 34: Supervisor Ii Output Relays

    Section 7 COMPRESSOR OPERATION 7.6 SUPERVISOR II OUTPUT RELAYS RELAY OPERATION RUN RELAY (K1) Contact closure energizes the compressor starter. *---DELTA (K2) A timed contact used to provide Wye---delta transition time. UNLOAD/LOAD (K3) Controls ON LOAD/OFF LOAD operation of the load control solenoid valve.
  • Page 35: General

    DRYER OPERATION 8.1 GENERAL service or indicate the beginning of a malfunction. While Sullair has built into this compressor/dryer Before starting the Sullair compressor/dryer, read controls and indicators to assist you in determining this section thoroughly and familiarize yourself with...
  • Page 36: Normal Operating Conditions

    Section 8 DRYER OPERATION psig (4.0 to 4.1 bar), immediately take corrective NOTE action utilizing the dryer troubleshooting section of this manual. 3. Open the air shutoff valve slowly and apply load to Add 1 psig (0.7 bar) to the minimum allowable suc- tion pressures referred to in manual for each 2,000 the compressor/dryer.
  • Page 37: Introduction

    PERIOD (HRS.) PERIOD (HRS.) PERIOD (HRS.) ---10_F to +90_F Sullube 32 8000 (I) 8000 (I) 4000 (II) (---23_C to +32_C) Sullair LLL---4---32 8000 (I) 8000 (I) 4000 (II) SRF 1/4000 4000 4000 4000 (II) (I) 8,000 hours or once a year.
  • Page 38 Section 9 COMPRESSOR MAINTENANCE AND TROUBLESHOOTING Figure 9 ---1 Fluid Filter (P/N 250026 ---982) WARNING Before doing compressor/dryer maintenance, disconnect compressor from power source and lock out power source. Isolate compressor/dryer from line pressure by closing recommended dis- charge shut---off valve and releasing all internal pressure from compressor/dryer.
  • Page 39 Section 9 COMPRESSOR MAINTENANCE AND TROUBLESHOOTING Figure 9 ---3 Separator Element DANGER DO NOT touch the electrical contacts, terminal or leads with any part of the body or any uninsulated metallic object. Severe electrical shock may oc- cur. PRESSURE REGULATOR ADJUSTMENT If pressure regulator adjustment is required, the adjustment procedure below should be followed: 1.
  • Page 40: Troubleshooting Introduction

    Should your problem persist after making the rec- 3. Remove the three (3) capscrews from the inlet ommended check, consult your nearest Sullair valve cover. representative or the Sullair Corporation factory. 9.8 TROUBLESHOOTING -- COMPRESSOR...
  • Page 41 Section 9 COMPRESSOR MAINTENANCE AND TROUBLESHOOTING 9.8 TROUBLESHOOTING -- COMPRESSOR (continued) SYMPTOM PROBABLE CAUSE REMEDY T1 HI Message (continued) Temperature RTD Malfunction Check connections from RTD. If adequate, replace RTD. P1 HI Message Discharge Pressure Exceeded Shutdown Level Because: P1 MAX--- 3psi (0.2 Bar) Exceeded for Pre--- Alarm P1 MAX Exceeded for Shutdown Unloading Device (i.e., Blowdown...
  • Page 42: Calibration

    Section 9 COMPRESSOR MAINTENANCE AND TROUBLESHOOTING NOTE ON TRANSDUCERS: Whenever a sensor is display mode: “ ”, “Y”, “B ”, PROG. Once suspected of fault, the recommended cause of ac- in calibration mode, you will see a screen like the tion is to measure the signal (pressure, tempera- following: ture, etc.) with an alternate calibrated instrument...
  • Page 43: Maintenance Record

    Section 9 COMPRESSOR MAINTENANCE AND TROUBLESHOOTING 9.10 MAINTENANCE RECORD MODEL NO. SERIAL NO. AUTHORIZED MAINTENANCE WORK PERFORMED DATE HOURMETER PERFORMED...
  • Page 44 NOTES...
  • Page 45: General

    Section 10 DRYER MAINTENANCE AND TROUBLESHOOTING 10.1 GENERAL system operation. As you proceed in reading this section, it will be 10.3 TROUBLESHOOTING INTRODUCTION (DRY- easy to see that Maintenance Program for the dryer is quite minimal. The use of service indicators will Before working on the refrigerant system, read the alert you when service maintenance is required.
  • Page 46: Troubleshooting

    Section 10 DRYER MAINTENANCE AND TROUBLESHOOTING 10.4 TROUBLESHOOTING -- DRYER (continued) SYMPTOM PROBABLE CAUSE REMEDY HEAD PRESSURE TOO LOW Low Ambient Temperature Increase ambient temperature. If ambient temperature is too low, dryer freeze--- up can take place. Add some type of head pressure control. Refrigerant Shortage Check for leaks in system;...
  • Page 47 NOTES...
  • Page 48 Section 11 ILLUSTRATIONS AND PARTS LIST ES-- 8 COMPRESSOR ASSEMBLY, EXPLODED VIEW...
  • Page 49: Procedure For Ordering Parts

    Bill of Lading for the compressor/dryer or from the Serial Number Plate located on the compressor/dryer. The genuine Sullair service parts listed meet or exceed the demands of this compressor. Use of replacement parts other than those approved by Sullair Corporation may lead to hazardous conditions over which Sullair Corporation has no control.
  • Page 50 Section 11 ILLUSTRATIONS AND PARTS LIST 11.2B RECOMMENDED SPARE PARTS LIST -- DRYER DESCRIPTION KIT NUMBER QUANTITY repair kit for separator filter 02250052---689 250022-- 965 (auto drain) 250024-- 295 (sight glass) 02250056-- 270 (o -- rings) repair kit for MPF---14 250024---361 250024-- 427 250019-- 453 repair kit for regulator valve 250017---280...
  • Page 51 Section 11 ILLUSTRATIONS AND PARTS LIST NOTES...
  • Page 52 Section 11 ILLUSTRATIONS AND PARTS LIST 11.3 INLET CONTROL, SEAL/DRIVE GEAR AND PARTS (ES-- 8)
  • Page 53 Section 11 ILLUSTRATIONS AND PARTS LIST 11.3 INLET CONTROL, SEAL/DRIVE GEAR AND PARTS (ES-- 8) part number description number quantity housing, drive 02250045---827 screw, flat hd M6 x 12MM 865006---012 washer 02250048---229 seat, minimum pressure valve (I) 02250047---162 stem, minimum pressure valve 02250047---163 spring, minimum pressure valve (I) 02250047---296...
  • Page 54 Section 11 ILLUSTRATIONS AND PARTS LIST 11.3 INLET CONTROL, SEAL/DRIVE GEAR AND PARTS (ES-- 8)
  • Page 55: Inlet Control, Seal/Drive Gear And Parts (Es

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.3 INLET CONTROL, SEAL/DRIVE GEAR AND PARTS (ES-- 8) (CONTINUED) part number description number quantity spring, inlet check 250042---088 stem, inlet valve 250035---584 element, thermal valve 045764 isolator, vibration 02250047---047 valve, shuttle 1/4” 408893 nipple, pipe 1/4”...
  • Page 56: Motor, Coupling, Fan And Parts (Es

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.4 MOTOR, COUPLING, FAN AND PARTS (ES-- 8)
  • Page 57 Section 11 ILLUSTRATIONS AND PARTS LIST 11.4 MOTOR, COUPLING, FAN AND PARTS (ES-- 8) part number description number quantity support, motor (15, 20, 25 HP/11, 15, 18.5 KW) 02250046---622 Ssupport, motor (30 HP/22 KW) 02250046---624 capscrew, M12 x 30MM 829312---030 housing, adaptor motor (15, 20, 25 HP/11, 15, 18.5 KW) 02250045---831...
  • Page 58 Section 11 ILLUSTRATIONS AND PARTS LIST 11.5 INLET FILTER, COMPRESSOR HOUSING/SUMP AND PARTS (ES-- 8)
  • Page 59 Section 11 ILLUSTRATIONS AND PARTS LIST 11.5 INLET FILTER, COMPRESSOR HOUSING/SUMP AND PARTS (ES-- 8) part number description number quantity filter, air cyclopac 6 1/2” (I) 043333 band, mounting 6 1/2” 043370 capscrew, M6 x 16MM 828006---016 washer, 6MM 865406---125 reducer, hose 2 1/2”...
  • Page 60 Section 11 ILLUSTRATIONS AND PARTS LIST 11.5 INLET FILTER, COMPRESSOR HOUSING/SUMP AND PARTS (ES-- 8)
  • Page 61: Inlet Filter, Compressor Housing/Sump And Parts (Es

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.5 INLET FILTER, COMPRESSOR HOUSING/SUMP AND PARTS (ES-- 8) (CONTINUED) part number description number quantity element, separator (III) 250035---239 plug, push---lok 1/4” tube 02250052---477 decal, fluid level see decal section bail lifting 02250054---858 plug, 1/2”---14 x M20 02250054---857 nut, hex M20 thin 02250055---630...
  • Page 62: Compressor Cooler System And Parts (Es

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.6 COMPRESSOR COOLER SYSTEM AND PARTS (ES-- 8)
  • Page 63 Section 11 ILLUSTRATIONS AND PARTS LIST 11.6 COMPRESSOR COOLER SYSTEM AND PARTS (ES-- 8) part number description number quantity insert, threaded blind 6MM 02250047---083 aftercooler 250040---092 capscrew, M6 x 12MM 829306---012 cooler, oil (15,20 HP/11,15KW) 250039---096 Scooler, oil (25,30 HP/18.5, 22KW) 02250046---054 capscrew, M6 x 20MM 829306---020...
  • Page 64: Refrigerant System (Dryer)

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.7 REFRIGERANT SYSTEM (DRYER)
  • Page 65 Section 11 ILLUSTRATIONS AND PARTS LIST 11.7 REFRIGERANT SYSTEM (DRYER) part number description number quantity gauge, suction 02250046---815 line, gauge 250022---040 tube, capillary 02250058---535 switch, fan cycling 02250058---534 elbow, sldr 90˚ 3/8” 805100---038 unit, condensing 02250058---533 02250061---601 Scompressor (I) S motor, fan (I) 406105 S blade, fan (I) 406106...
  • Page 66: Air System (Dryer)

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.8 AIR SYSTEM (DRYER)
  • Page 67 Section 11 ILLUSTRATIONS AND PARTS LIST 11.8 AIR SYSTEM (DRYER) part number description number quantity u---bolt, clr mntg 250033---043 evaporator 250027---266 coupling, pipe 1” 801215---040 nipple, pipe 1” 822216---000 elbow, pipe 1” 801515---040 nipple, pipe 1” x 11 1/2” 822116---115 union, pipe 1”...
  • Page 68: Frame, Canopy And Parts

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.9 FRAME, CANOPY AND PARTS...
  • Page 69 Section 11 ILLUSTRATIONS AND PARTS LIST 11.9 FRAME, CANOPY AND PARTS part number description number quantity panel, corner RH 02250056---219 panel, center 224585 panel, door assy 014620 support, LH 02250056---215 panel, corner LH 224584 panel, roof assy 02250058---503 plenum 02250056---172 panel, 02250056---220 panel, compressor/dryer mtg...
  • Page 70 Section 11 ILLUSTRATIONS AND PARTS LIST 11.10 DECAL GROUP...
  • Page 71: Decal Group

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.10 DECAL GROUP part number description number quantity sign, warning --- compressor fluid fill cap 049685 sign, danger electrocution 049850 sign, warning --- hot surfaces 407408 decal, warning auto start 041065 decal, danger breath air 250027---935 sign, warning “food grade”...
  • Page 72 Section 11 ILLUSTRATIONS AND PARTS LIST 11.10 DECAL GROUP ...
  • Page 73 Section 11 ILLUSTRATIONS AND PARTS LIST 11.10 DECAL GROUP (CONTINUED) part number description number quantity decal, compressor fluid SRF 1/4000 (I) 02250069---391 decal, earth ground 02250075---046 Sdecal, protective earth ground (not shown) 02250075---045 Sdecal, PE designation (not shown) 02250075---540 decal, danger hi voltage 042218 sign, warning ground fault 049852...
  • Page 74 Section 11 ILLUSTRATIONS AND PARTS LIST 11.10 DECAL GROUP...
  • Page 75 SRD norm. op. conditions 02250046---916 decal, warning HCFC 22 02250054---320 decal, controls kit 250031---275 decal, Sullair 2 1/4” x 18” black 02250059---052 Sdecal, Sullair 3 1/2” x 28” black 02250059---058 PLEASE NOTE: WHEN ORDERING PARTS, INDICATE SERIAL NUMBER OF COMPRESSOR/DRYER.
  • Page 76: Wiring Diagram

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.11 WIRING DIAGRAM -- FULL VOLTAGE (STANDARD)
  • Page 77: Wiring Diagram

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.12 WIRING DIAGRAM -- FULL VOLTAGE (DELUXE)
  • Page 78: Wiring Diagram

    Section 11 ILLUSTRATIONS AND PARTS LIST 11.13 WIRING DIAGRAM -- WYE DELTA 60 HZ...
  • Page 79 NOTES...
  • Page 80 SULLAIR CORPORATION Subsidiary of Sundstrand Corporation 3700 East Michigan Boulevard Michigan City, Indiana 46360 U.S.A. Telephone: 1-- 800-- SULLAIR (U.S.A. Only) or 1-- 219-- 879-- 5451 Fax: (219) 874-- 1253 Telephone: 1-- 888-- SULLAIR (Parts) Fax: (219) 874-- 1835 (Parts) Fax: (219) 874-- 1205 (Service) Printed in U.S.A.