Item
g) PulseGenerator
Clock Pre Scaler
Pulse Generator Clock (MHz)
Pulse Generator Selector
Pulse Generator Length
Pulse Generator Length (ms)
Pulse GeneratorFrequency (Hz) 0.429154 to 450000
Pulse Generator Start Point
Pulse Generator Start Point
(ms)
Pulse Generator End Point
Pulse Generator End Point (ms) 0.00222222 to
Pulse Generator Pulse Width
(ms)
Pulse Generator Repeat Count
Pulse Generator Clear Activation
Pulse Generator Clear Source
Pulse Generator Clear Inverter
Pulse Generator Clear Sync
Mode
Setting range
Default value
1 to 4096
165
0.0181274 to 74.25
0.45
Pulse Generator 0
Pulse Generator 0
1 to 1048575
30000
0.002222222 to
66.6667
2330.17
15
0 to 1048574
0
0 to 2330.16
0
1 to 1048575
15000
33.3333
2330.17
-1.79769e+308 to
33.3333
1.79769e+308
0 to 255
0
Off, HighLevel, LowLevel,
Off
RisingEdge, FallingEdge
Low
True, False
False
Async Mode,
Async Mode
Sync Mode
— 49 —
Description
Configure pulse generator settings.
Set the division value for the prescaler (12 bit)
using PixelClock as the base clock.
Set the clock used for the pulse generator.
This value is calculated using the
[ClockPreScaler] value as a base.
Select the pulse generator.
Set the maximum count-up value as a
clock count.
Set the maximum count-up value in
milliseconds.
This value is calculated using the
[PulseGeneratorLength] value as a base.
The setting range varies depending on the
[ClockPreScaler] value.
Set the maximum count-up value as a
frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
Set the start point of the High interval as a clock
count. When the counter reaches this value, the
output will be 1.
Set the start point of the High interval in
milliseconds.
When the counter reaches this value, the output will
be 1. The setting range varies depending on the
[ClockPreScaler] value.
Set the start point of the Low interval as a
clock count.
When the counter reaches this value, the output will
be 0.
Set the start point of the Low interval in
milliseconds.
When the counter reaches this value, the output will
be 0. The setting range varies depending on the
[ClockPreScaler] value.
Display the High interval width of the pulse
in milliseconds.
The duration between the Start Point and End Point is
calculated. The setting range varies depending on the
[ClockPreScaler] value.
Set the repeat count for the counter.
When this is set to [0], a free counter is enabled with
no repeat limit.
Set the clear signal condition for the count
clear input of the pulse generator.
Select the count clear input signal source.
[Setting range]
Low, High, AcquisitionTriggerWait,
FrameTriggerWait, FrameActive, ExposureActive,
JAIFVAL, JAILVAL, UserOutPut0, UserOutPut1,
Action1, Action2, Line5, Nand0, Nand1
Select whether to invert the polarity of the
count clear input signal.
Select the sync mode for the count clear
input signal.