JAI GO-5100MP-PGE User Manual page 33

5.1m cmos digital progressive scan polarized camera
Table of Contents

Advertisement

■ When [ExposureMode] is [Timed]
Example: When [TriggerSource] is set to [Line 5 - OptIn1] and [OptInFilterSelector] is set
to [10 µs]
• TriggerOverlap:Off
Trigger
Sensor
Exposure
ExposureActive
Readout
8 bit
10 bit packed
10 bit
*) If the exposure time is longer than (input trigger cycle - t3), the next trigger input will not
be accepted.
t1
t2
Exposure time
t1
10 μs
(minimum)
Next trigger disabled
t3
t2
40 μs
79 μs
— 33 —
GO-5100MP-PGE
Next trigger
Input enabled*
//
t3
(minimum)
28 ms
55 ms